Construction Charts

Jack Stud Chart – Number Required, Sizes and Framing Guide

Jack Stud Chart: IRC Requirements, Sizes & Lengths | ConcreteCalculate.com
2024 IRC R602.7 · Header Support Reference

Jack Stud ChartNumber Required, Sizes and Framing Guide

A code-based reference for carpenters, framers, inspectors and homeowners: how many jack studs support each header end, how jack studs differ from king and cripple studs, and how to find bearing length and cut length.

2024 IRC header tablesKing stud countsCut-length formulasBearing widthLast updated: October 2026
Jump to the Chart

Key Facts

  • The number of jack studs comes from the IRC header tables, not from opening width alone. The 2024 tables list one, two or three jack studs per header end.
  • Jack studs support the header. King studs run full height. Their counts are separate checks (Tables R602.7(1) and (2) vs. Table R602.7.5).
  • Jack stud length = header underside elevation minus bottom plate top elevation.

Jack Stud Chart: Quick Reference

Required jack studs per header end from the 2024 IRC, with every condition stated.

The number of jack studs under a header comes from the IRC header tables, not from the opening width alone. This chart shows one clearly defined slice of the 2024 IRC so every number has stated conditions. For choosing the header itself, see the Header Size Chart.

How to Read This Chart

(2) 2×8 means a two-ply header made from nominal 2×8 lumber. Choose your building width, find the header size, and read the maximum tabulated span and the jacks per end (NJ). Jacks per end is the number at each end of the header. The span is the maximum for that header and width. A shorter opening does not automatically reduce the jack count; use a permitted header-and-support combination from the table.

2024 IRC Table R602.7(1), exterior bearing wall supporting roof and ceiling only, 30 psf ground snow load. Jacks per end is the number required at each end of the header, not the total for the opening.
Header size12-ft building: max. spanJacks per end24-ft building: max. spanJacks per end36-ft building: max. spanJacks per end
(2) 2×44 ft 0 in.13 ft 1 in.12 ft 7 in.1
(2) 2×66 ft 0 in.14 ft 7 in.13 ft 10 in.1
(2) 2×87 ft 7 in.15 ft 9 in.14 ft 10 in.2
(2) 2×109 ft 0 in.16 ft 10 in.25 ft 9 in.2
(2) 2×1210 ft 7 in.28 ft 1 in.26 ft 10 in.2
  • Conditions: exterior bearing wall, roof and ceiling only, 30 psf ground snow load, No. 2 grade lumber of the listed species groups, header top laterally braced as the table assumes, building widths of 12, 24 and 36 ft.
  • This table does not give the number of full-height king studs. Those are checked separately in IRC Table R602.7.5, shown below.
  • Snow loads of 50 and 70 psf and floor-supporting conditions are not in this simplified chart.
  • The adopted IRC edition, table footnotes, approved plans and local amendments govern.

Source: 2024 International Residential Code, Table R602.7(1), exterior bearing walls, roof and ceiling only, 30 psf ground snow load, No. 2 grade Douglas fir-larch, hem-fir, southern pine and spruce-pine-fir. Building width is measured perpendicular to the ridge, and widths between the listed columns may be interpolated.

Jack, king and cripple studs around a window openingFront elevation of a framed window opening showing the double top plate, bottom plate, header, one jack stud and one king stud at each header end, cripple studs above the header, the rough sill and cripple studs below the sill. Arrows trace header load down through the jack studs.Rough openingDouble top plateCripple stud above headerHeader spans the openingRough sillBottom plateKing stud (full height)Jack stud (supports header)Cripple studs below sillOrange arrows show loads moving from above, into the header, down the jack studs and into the bottom plate and the structure below.Illustrative proportions, one possible layout. The code tables set the required jack and king stud counts.
Jack studs support the header ends, king studs run full wall height, and cripple studs complete the framing above and below a window opening.
Residential wood-framed door opening showing jack studs supporting the header, full-height king studs, top plate and bottom plate.
Residential door framing showing jack studs supporting the header beside full-height king studs.

What Is a Jack Stud?

Definition and Purpose

A jack stud is a shorter vertical framing member placed directly beneath the end of a header at the side of a door or window opening. It carries the header’s end reaction down into the bottom plate and the structure below. Jack studs also help hold the rough-opening geometry.

A jack stud normally runs from the top of the bottom plate to the underside of the header. It works with the full-height stud beside it to form the opening assembly.

Jack Stud vs. Trimmer Stud

In U.S. wood framing, jack stud and trimmer stud usually mean the same member. The IRC uses the term jack stud and counts them with the symbol NJ.

Jack Studs in Door and Window Framing

Door Openings

A door opening has a header, jack and king studs on each side, and cripple studs above the header. It has no sill, so the jack studs usually run from the bottom plate to the header. See the Door Rough Opening Chart for opening dimensions.

Window Openings

A window opening adds a rough sill and short cripple studs below it. The sill closes the bottom of the opening, but the header’s load goes down the jack studs, not through the sill. See the Window Rough Opening Chart for rough-opening sizes.

Header Support

In both cases the jack studs provide the bearing under the header ends. The number of jack studs and the number of full-height studs are separate code checks.

Jack Stud Building Code Requirements

The 2024 International Residential Code sets header support in Section R602.7. The tables list NJ, the number of jack studs needed to support each end of the header, for each header size, span, building width and load condition.

Section R602.7 and related provisions.
IRC referenceWhat it covers
R602.7Headers: where headers are required and where to find spans
Table R602.7(1)Header spans and jack studs (NJ) for exterior bearing walls
Table R602.7(2)Header spans and jack studs (NJ) for interior bearing walls
Table R602.7(3)Header spans for qualifying open porches
R602.7.4Headers in interior and exterior nonbearing walls
R602.7.5 and Table R602.7.5Header support and the minimum number of full-height studs at each end
Table R602.3(1)Fastening schedule for framing connections

IRC R602.7

Headers over openings in bearing walls must be sized from the tables or designed. The maximum spans themselves are covered in the Header Span Chart.

Exterior and Interior Header Tables

Table R602.7(1) covers exterior bearing walls and varies by ground snow load and by what the wall supports. Table R602.7(2) covers interior bearing walls and varies by the number of floors supported.

Header Support Rules

Section R602.7.5 requires headers to be supported at each end by jack studs or approved framing anchors as the tables allow. The full-height stud next to each header end must be end-nailed to the header in accordance with Table R602.3(1), and the minimum count of full-height studs follows Table R602.7.5.

Edition and Local Adoption

The 2024 IRC is a reference edition. The locally adopted code, any amendments and the approved plans control the job.

How Many Jack Studs Are Required?

The IRC range runs from one to three jack studs per end, and which one applies depends on the header, the building width, the roof and snow load and what the wall supports. Look at these rows from the 2024 table.

2024 IRC Table R602.7(1), roof and ceiling only, 30 psf ground snow load. Each row is one table entry, not a general rule.
HeaderBuilding widthMax. tabulated spanJacks per end
(2) 2×612 ft6 ft 0 in.1
(2) 2×624 ft4 ft 7 in.1
(2) 2×836 ft4 ft 10 in.2
(2) 2×1024 ft6 ft 10 in.2
(1) 2×1236 ft4 ft 7 in.3

Single Jack Studs

One jack per end is common for smaller headers and narrower buildings. Where the table lists one, an approved framing anchor may replace it, as explained later.

Double Jack Studs

Two jacks per end appear as headers get larger or loads get heavier. Doubling the jacks doubles the bearing length under the header end.

One, two and three jack studs under a header endThree front elevations of a header end. A single jack stud gives 1-1/2 inches of combined bearing length, two jack studs give 3 inches, and three jack studs give 4-1/2 inches. A full-height stud sits beside the jack studs in each view.One jack studKing stud (full height)HeaderJackBottom plateb = 1 × 1.5 = 1-1/2 in.Two jack studsKing stud (full height)HeaderJackJackBottom plateb = 2 × 1.5 = 3 in.Three jack studsKing stud (full height)HeaderJackJackJackBottom plateb = 3 × 1.5 = 4-1/2 in.Combined bearing length is geometry only. The code table sets the jack and full-height stud counts. Standard 2× lumber, 1-1/2 in. actual thickness.
Single, double, and triple jack-stud arrangements provide different bearing lengths beneath a header, subject to the required structural design.

Triple Jack Studs

Three jacks per end occur in heavier cases, such as a single-ply 2×12 header in a 36 ft wide building. Heavier snow columns can also reach three jacks for large headers.

Wood-framed wall opening showing a built-up lumber header supported by double jack studs, with full-height king studs, top plate, and bottom plate labeled.
Residential wood framing illustration showing a built-up header, such as two 2×10 lumber members, supported by double jack studs on both sides of a wide opening. Full-height king studs and wall plates are labeled to explain the framing components.
Same table and loading as above. A (2) 2×10 header needs 1 or 2 jacks depending on building width.
HeaderBuilding widthMax. tabulated spanJacks per end
(2) 2×824 ft5 ft 9 in.1
(2) 2×1024 ft6 ft 10 in.2
(2) 2×1012 ft9 ft 0 in.1
(2) 2×1036 ft5 ft 9 in.2

No Width-Only Rule

Never use a rule such as one jack stud for openings up to 4 ft and two for 4 to 8 ft. The IRC tables do not work that way.

Jack Stud Chart for Exterior Bearing Walls

The main chart at the top of the page is the exterior bearing-wall slice. Here is how its conditions change the answer.

Header Sizes

Bigger headers span farther, but they can also need more jack studs because they carry more load to each end.

Building Width

Width is measured perpendicular to the ridge. A wider building puts more roof load on the wall, so spans fall and jack counts rise, as the 12, 24 and 36 ft columns show.

Roof and Snow Loads

Heavier ground snow shortens spans and can add a jack. The table below uses a 24 ft building to show the effect.

2024 IRC Table R602.7(1), roof and ceiling only, 24 ft building width. Each cell shows max. span and jacks per end.
Header30 psf: span / jacks50 psf: span / jacks70 psf: span / jacks
(2) 2×64 ft 7 in. / 13 ft 11 in. / 13 ft 6 in. / 2
(2) 2×85 ft 9 in. / 15 ft 0 in. / 24 ft 5 in. / 2
(2) 2×106 ft 10 in. / 25 ft 11 in. / 25 ft 3 in. / 2
(2) 2×128 ft 1 in. / 26 ft 11 in. / 26 ft 2 in. / 2

The full 2024 table also covers headers that support additional floors. Use the complete code table, not this slice, for those conditions.

Jack Stud Chart for Interior Bearing Walls

Interior bearing walls carry floor loads, not snow, so their table has no snow-load columns. The conditions are the number of floors supported and the building width.

One-Floor Loads

2024 IRC Table R602.7(2), interior bearing wall supporting one floor only.
Header size12-ft building: max. spanJacks per end24-ft building: max. spanJacks per end36-ft building: max. spanJacks per end
(2) 2×44 ft 1 in.12 ft 10 in.12 ft 4 in.1
(2) 2×66 ft 1 in.14 ft 4 in.13 ft 6 in.1
(2) 2×87 ft 9 in.15 ft 5 in.14 ft 5 in.2
(2) 2×109 ft 2 in.16 ft 6 in.25 ft 3 in.2
(2) 2×1210 ft 9 in.17 ft 7 in.26 ft 3 in.2

Two-Floor Loads

Two floors cut the spans sharply. A (2) 2×6 header spans 6 ft 1 in. in a 12 ft building under one floor but only 3 ft 11 in. under two. The one-floor chart must never be used for a wall supporting two floors.

2024 IRC Table R602.7(2), interior bearing wall supporting two floors, selected rows only. Use the full table for larger headers.
Header size12-ft building: max. spanJacks per end24-ft building: max. spanJacks per end36-ft building: max. spanJacks per end
(2) 2×42 ft 7 in.11 ft 11 in.11 ft 7 in.1
(2) 2×63 ft 11 in.12 ft 11 in.22 ft 5 in.2
(2) 2×85 ft 0 in.13 ft 8 in.23 ft 1 in.2

Header Support

Header spans in both tables assume the header top is laterally braced by perpendicular framing. Where it is not (for example, cripple studs bearing on the header), the tabulated spans for 2×8, 2×10 and 2×12 headers are multiplied by 0.70, or the header must be designed. Where the table lists one jack, an approved framing anchor can replace it.

Jack Studs for Nonbearing Walls

Section R602.7.4 says load-bearing headers are not required in interior or exterior nonbearing walls.

Nonbearing Headers

A nonbearing wall carries only its own weight, so the bearing-wall header tables do not apply to it.

IRC Exceptions

For openings up to 8 ft wide, a single flat 2×4 may be used as a header in a nonbearing wall if the vertical distance to the parallel nailing surface above is not more than 24 inches. For such nonbearing headers, cripples or blocking are not required above the header.

Framing Requirements

Even where no structural header is needed, the opening still needs framing that suits the finishes and any bracing or connection requirements. Check the plans before assuming a partition is nonbearing.

Confirm the Wall Is Nonbearing

Do not treat a wall as nonbearing just because it is interior. Check the joist and rafter direction and the approved plans first.

Jack Stud vs. King Stud

Jack and king studs sit side by side, which is why they get confused. They have different jobs and different code counts.

Terminology for a framed opening.
Framing memberPositionMain functionTypical length
Jack stud (trimmer)Directly below the header endSupports the header reactionBottom plate to header underside
King studBeside the jack and the openingFull-height framing and the connection path to the platesBottom plate to top plate
Cripple stud above headerHeader to top plateTransfers load where applicable; provides framing and backingHeader top to top plate
Cripple stud below windowBottom plate to rough sillSupports the sill and completes the framingBottom plate to rough sill
HeaderAcross the openingCarries loads to its supportsSized for the opening and load

Location

The jack is inside, directly under the header. The king is outside it and runs the full wall height.

Structural Function

The jack bears the header. The king ties the opening assembly to the top and bottom plates and takes the end nailing from the header.

Required Counts

The jack count comes from Tables R602.7(1) and R602.7(2). The full-height count comes from Table R602.7.5. One does not set the other. Wall layout is in the Stud Spacing Chart.

Jack Stud vs. Cripple Stud

A cripple stud is a short stud above a header or below a window sill.

Above-Header Cripples

These run from the top of the header to the top plate. In a bearing wall they can pass vertical load to the header, so they should not be called nonstructural.

Below-Sill Cripples

These run from the bottom plate to the rough sill and support the sill and window framing.

Framing Differences

Cripples bearing on the header mean its top is not laterally braced by perpendicular framing, so the 0.70 span factor in the table footnotes applies to 2×8, 2×10 and 2×12 headers, unless the header is designed. For example, a (2) 2×10 header tabulated at 6 ft 10 in. (82 in.) would be limited to about 57 in. (82 × 0.70 = 57.4 in.). Confirm the jack count with the code footnotes or the designer.

King Stud Requirements Under IRC R602.7.5

Full-height studs, often called king studs, run from the bottom plate to the top plate beside the opening. Table R602.7.5 sets the minimum number at each end of an exterior header from the header span and the wind condition. These are full-height stud counts, not jack stud counts.

Full-Height Stud Counts

2024 IRC Table R602.7.5. Category A: ultimate design wind speed below 140 mph, Exposure B, or below 130 mph, Exposure C. Category B: ultimate design wind speed of 115 mph or less, Exposure B.
Maximum header spanWind category A: full-height studs per endWind category B: full-height studs per end
4 ft11
6 ft21
8 ft21
10 ft32
12 ft32
14 ft32
16 ft42
18 ft42
  • For spans between those listed, use the count for the next larger listed span.
  • The tabulated counts apply where jack studs support the header at each end in accordance with Table R602.7(1).
  • Where an approved framing anchor replaces a jack stud, the full-height count must follow the wind category A requirements (below 140 mph, Exposure B).

Wind Conditions

The lower category B column applies only up to 115 mph in Exposure B. Heavier wind raises the count. For example, a header spanning 6 ft needs two full-height studs per end in category A but one in category B.

Header Span

The count can exceed the jack count. A 12 ft header needs three full-height studs per end in category A even if the jack table calls for two jacks.

Source: 2024 IRC Table R602.7.5, Minimum Number of Full-Height Studs at Each End of Headers in Exterior Walls.

Jack Stud Sizes and Lumber Dimensions

2×4 and 2×6 Studs

Jack studs normally match the wall studs, so a 2×4 wall uses 2×4 jacks and a 2×6 wall uses 2×6 jacks. The jack should be as deep as the wall so the header and finishes stay flush.

Actual Dimensions

Dimension lumber is smaller than its name. The table below lists the standard dressed sizes. The 1-1/2 in. thickness is the number that sets bearing length, and the depth numbers are what you subtract when finding header depth. See the Lumber Size Chart for more sizes.

Standard dressed dimension lumber. Engineered wood products and special-order lumber can differ.
Nominal lumberActual thicknessActual width
2×41-1/2 in.3-1/2 in.
2×61-1/2 in.5-1/2 in.
2×81-1/2 in.7-1/4 in.
2×101-1/2 in.9-1/4 in.
2×121-1/2 in.11-1/4 in.

Lumber Selection

Studs must meet the minimum grade in IRC Section R602.2, and the header tables assume No. 2 grade header lumber. Do not swap in a larger or different member without checking compatibility and loads against the plans.

Jack Stud Length Chart

Header Underside Elevation

Jack length depends on where the underside of the header sits, not on the wall height alone.

Bottom Plate Elevation

Measure from the top of the bottom plate, which is 1-1/2 in. above the floor reference in this example.

Cut-Length Examples

Illustrative assembly: top of bottom plate at 1-1/2 in., underside of double top plate at 91-1/2 in., so Hu = 91.5 – 1.5 = 90 in. These are not universal jack-stud lengths.
Header member depthActual header depth DhJack cut length Lj = 90 – Dh
2×65-1/2 in.84-1/2 in.
2×87-1/4 in.82-3/4 in.
2×109-1/4 in.80-3/4 in.
2×1211-1/4 in.78-3/4 in.

If the header is installed lower to leave room for cripple studs above it, the cut length must be recalculated from the actual header underside elevation. The ply count does not change the depth, so a (2) 2×10 header still has a 9-1/4 in. depth.

How to Calculate Jack Stud Length

Formula

Use the elevation-based formula when you know where the header underside sits. Use the header-depth formula when the header sits directly under the top plates.

Measurements

Take the measurements from the actual installed header and plates, not from the plan. Rough-opening dimensions must be verified in the field.

Jack stud cut length exampleElevation showing a 90 inch clear height between the top of the bottom plate and the underside of the double top plate, a 2 by 10 header with an actual depth of 9-1/4 inches directly beneath the top plates, and the resulting jack stud cut length of 80-3/4 inches.Bottom plateDouble top plateHeader: 2×10, actual depth 9-1/4 in.Opening (clear span between jack studs)Hu = 90 in.(clear height)Dh = 9-1/4 in.Lj = 80-3/4 in.jack stud cut lengthLj = Hu – Dh = 90 – 9.25 = 80.75 in.Valid only when the header sits directly under the top plates. Vertical dimensions are to scale; stud widths are exaggerated for legibility.
Example jack-stud cut length calculated from the vertical framing clearance and actual header depth.

Worked Examples

Elevation-Based Jack Stud Length

Lj = Eh – Eb

Variables: Lj = jack stud cut length; Eh = elevation of the header underside; Eb = elevation of the top of the bottom plate (same datum for both)

Given: Header underside at 83-1/4 in., top of bottom plate at 1-1/2 in.
1
Lj = 83.25 – 1.5
2
Lj = 81.75 in.
Result: 81-3/4 in. jack stud cut length

Practical interpretation: This is the geometric length for the stated elevations. Field dimensions and tolerances must still be checked.

Header-Depth Jack Stud Length

Lj = Hu – Dh

Variables: Hu = clear distance from the top of the bottom plate to the underside of the top plates; Dh = actual header depth

Given: Hu = 90 in.; actual 2×10 header depth 9-1/4 in.
1
Lj = 90 – 9.25
2
Lj = 80.75 in.
Result: 80-3/4 in.

Practical interpretation: Use this form only when the header sits directly under the top plates. If cripples or other framing sit between them, use the elevation formula.

Construction worker measuring jack stud length from the top of the bottom plate to the underside of a wood header, with king studs and framing components labeled.
A construction worker measures the required jack stud (trimmer) length from the top of the bottom plate to the underside of the header. The illustration identifies the king studs, header, and bottom plate to demonstrate accurate jack stud measurement during residential wall framing.

Jack Stud Bearing Width

Single and Double Jacks

Each standard 2× jack adds 1-1/2 in. of bearing length along the header. Two jacks give 3 in.

Standard 2× lumber, 1-1/2 in. actual thickness. Geometry only.
Jack studs at one header endCombined nominal bearing length along the header
11-1/2 in.
23 in.
34-1/2 in.
46 in.

Triple Jacks

Combined Bearing Length

b = nj × t

Variables: b = combined bearing length along the header; nj = jack studs at one end; t = actual thickness of one jack stud

Given: Three standard 2× jack studs, t = 1.5 in.
1
b = 3 × 1.5
2
b = 4.5 in.
Result: 4-1/2 in. nominal bearing length

Practical interpretation: This assumes alignment and full bearing. It does not establish structural adequacy.

Bearing Limitations

Geometric bearing length is not the same as bearing capacity. Allowable compression perpendicular to the grain, the header reaction and the load path below all decide whether the bearing is adequate. The code tables already account for those checks, which is why the count comes from the table.

Jack Stud Load Path and Structural Support

Header End Reactions

A header acts like a short beam. Its load splits between its two supports, so each end reaction is half the total for a uniform load.

Approximate Header End Reaction (educational)

R = w × L ÷ 2

Variables: w = uniform load per foot of header; L = header span; R = reaction at each end

Given: Span 6 ft; uniform load 300 lb per linear foot
1
R = 300 × 6 ÷ 2
2
R = 900 lb
Result: an idealized 900 lb reaction at each end

Practical interpretation: This is a statics illustration. Actual loads come from structural design, and the jack stud count cannot be found by dividing the reaction by a presumed universal stud capacity.

Vertical Load Transfer

The load path runs from the roof or floor above, through the top plates and any cripple studs, into the header, then through the jack studs to the bottom plate and the structure below. The first drawing on this page shows that path.

Continuous Support

The Load Path Must Continue Below

Jack studs cannot make up for a missing or misaligned support below the bottom plate. Floor framing, blocking, beams or the foundation must carry the load down. For beam loading context, see the Wood Beam Span Chart.

Jack Studs for Door Openings

Interior Doors

Interior doors in bearing walls follow the interior header table. Interior doors in nonbearing walls may use the nonbearing header provision. Door framing dimensions are in the Door Rough Opening Chart.

Exterior Doors

Exterior doors are usually in bearing walls and use the exterior table. Entry doors with sidelights can create wide openings that need a header selected for the whole width.

Wide Openings

Wider openings carry larger reactions and more often need two or three jacks and extra full-height studs.

Garage door openings are wide and are frequently outside what dimension-lumber header tables cover, so they are commonly designed by an engineer or use engineered headers and special high-wind framing details.

Jack Studs for Window Openings

Header

A window header is sized like a door header from the same tables. The window’s own rough-opening size is in the Window Rough Opening Chart.

Rough Sill

The rough sill is a flat framing member at the bottom of the opening. It does not carry the header load.

King and Jack Placement

Place the jack studs inside the king studs at each side so the header ends sit on the jacks. The jacks run from the bottom plate to the header underside, and the sill fits between them.

Cripple Stud Arrangement

Cripples go above the header to the top plate and below the sill to the bottom plate, usually at the wall’s stud spacing.

Jack Studs for Large Headers and Wide Openings

Multiple Jacks

Large reactions can call for two or three jacks per end, and the full-height stud count grows with span as Table R602.7.5 shows. The single-ply row below reaches three jacks in a 36 ft building.

2024 IRC Table R602.7(1), roof and ceiling only, 30 psf ground snow load.
Header size12-ft building: max. spanJacks per end24-ft building: max. spanJacks per end36-ft building: max. spanJacks per end
(1) 2×127 ft 1 in.25 ft 5 in.24 ft 7 in.3

LVL Headers

The IRC tables above are for dimension lumber. Engineered headers such as LVL have their own bearing length and support requirements set by the manufacturer. Do not apply the sawn-lumber chart to an LVL header. For span selection, see the LVL Span Chart.

Engineered Details

Wide openings and concentrated loads call for an engineered detail, including the support beneath the jack studs.

Header Size vs. Jack Stud Count

Header selection answers span and loading. Jack stud selection answers end support. They are separate checks that interact through the table.

Header Span

A (2) 2×8 spans 5 ft 9 in. with one jack per end in a 24 ft building, and a (2) 2×10 spans 6 ft 10 in. but needs two.

2024 IRC Table R602.7(1), roof and ceiling only, 30 psf ground snow load.
HeaderBuilding widthMax. spanJacks per end
(2) 2×824 ft5 ft 9 in.1
(2) 2×1024 ft6 ft 10 in.2

End Bearing

A bigger header often moves more load to each end, which is why the count can rise.

Separate Design Checks

A header may be large enough to span an opening and still need more jacks. Adding jacks does not make an undersized header adequate. Full header sizing stays on the Header Size Chart.

Jack Stud Alternatives and Header Hangers

Approved Framing Anchors

A footnote to Tables R602.7(1) and R602.7(2) says that where the number of required jack studs equals one, the header is permitted to be supported by an approved framing anchor attached to the full-height wall stud and to the header. APA advanced-framing guidance also shows header hangers and single-ply headers as framing options.

IRC Exceptions

This exception applies only to the single-jack case. It does not remove jack studs from openings that need two or three, and it changes the full-height stud count: Table R602.7.5 requires the wind category A counts where an anchor replaces a jack stud.

Installation Requirements

Use the Exact Approved Connector

The connector must have an approved installation, adequate capacity for the actual reaction, and the manufacturer’s specified fasteners. Header hangers from different makers are not interchangeable.

A single flat member used as a header (Section R602.7.1) has its own framing and nailing rules and is a different detail.

Jack Stud Fastening and Connections

This page does not set one nail schedule for every jack stud assembly. The IRC lists specific rows, and the plans or connector maker may require more.

Selected rows. Use the complete table and the approved plans.
ConnectionListed fastening alternativesMethod
Built-up header (2 in. to 2 in. with 1/2 in. spacer)16d common (3-1/2 × 0.162 in.) at 16 in. o.c. each edge; or 16d box (3-1/2 × 0.135 in.) at 12 in. o.c. each edgeFace nail
Continuous header to stud5-8d box (2-1/2 × 0.113 in.); or 4-8d common (2-1/2 × 0.131 in.); or 4-10d box (3 × 0.128 in.)Toe nail
Adjacent full-height stud to end of header4-16d box (3-1/2 × 0.135 in.); or 3-16d common (3-1/2 × 0.162 in.); or 4-10d box (3 × 0.128 in.); or 4-3 × 0.131 in. nailsEnd nail
Top or bottom plate to stud3-16d box; or 2-16d common (3-1/2 × 0.162 in.); or 3-10d box; or 3-3 × 0.131 in. nailsEnd nail
Stud to stud, not at braced wall panels16d common (3-1/2 × 0.162 in.) at 24 in. o.c.; or 10d box (3 × 0.128 in.) or 3 × 0.131 in. nails at 16 in. o.c.Face nail

Jack-to-King Connections

The fastening schedule has no separate jack-to-king row, so ask the building official or designer how the jack and king are to be connected unless the plans show it. The stud-to-stud row is the closest listed entry.

Header Fastening

The full-height stud next to the header end is end-nailed to the header, and a continuous header is toe-nailed to the stud, as the table shows. Nail dimensions are in the Framing Nail Size Chart and the general Nail Size Chart.

Connector Requirements

Where a framing anchor is used, use the manufacturer’s connector nails and follow its installation instructions exactly.

How to Frame a Door or Window with Jack Studs

This sequence is a layout guide, not structural design. The plans and code tables decide sizes and counts.

Layout

  1. Confirm the plans, the wall type (bearing or nonbearing) and the header size.
  2. Lay out the rough opening and mark king, jack and cripple locations.
  3. Install the full-height king studs.

Cutting and Installation

  1. Measure the header underside elevation and cut the jack studs to length.
  2. Install the jack studs tight against the king studs and on the bottom plate.
  3. Set the header on the jack studs, tight to the top plates or with cripples above.
  4. Fasten the header, jacks and kings as the code schedule or plans require.

Inspection

  1. Check bearing, plumb, rough-opening size and the support below the bottom plate.

How to Estimate Jack Stud Quantities

Per-Opening Count

Find the required count from the applicable table or plan first. Then multiply by two ends.

Material quantity only. The required count comes first from the code table or plans.
Opening configurationJacks at left endJacks at right endTotal jack studs
Single jacks112
Double jacks224
Triple jacks336
Four per end448

Total Jack Studs for One Opening

Nj = NL + NR

Variables: Nj = total jack studs; NL, NR = jack studs at the left and right header ends

Given: Two jack studs required at each end
1
Nj = 2 + 2
2
Nj = 4
Result: 4 jack studs

Practical interpretation: This does not include full-height king studs or cripple studs.

Multiple-Opening Count

Jack Studs for Several Openings

Ntotal = n × 2 × N per end

Variables: n = number of openings; N per end = required jacks per end (symmetrical supports)

Given: Three openings, each with two jacks per end
1
Ntotal = 3 × 2 × 2
2
Ntotal = 12
Result: 12 jack studs

Practical interpretation: Add a separate allowance for waste or damaged lumber only when preparing a purchasing estimate.

Material Takeoff

Count king studs and cripples separately. A takeoff for one opening with two jacks and one king per side has four jacks and two kings. Waste allowances belong to the purchasing estimate, not to the code count.

Common Jack Stud Framing Mistakes

Incorrect Counts

Using one jack stud for every opening

Some table cells need two or three.

Confusing jack studs with king studs

They have separate jobs and separate code counts.

Ignoring full-height stud requirements

Check Table R602.7.5 as well.

Selecting jacks using only opening width

Header, width and load decide the count.

Using a header chart for the wrong load condition

Floors above and snow change the table.

Ignoring building width and snow load

Both change the span and the count.

Using a nonbearing-wall rule in a bearing wall

Nonbearing allowances do not apply to bearing walls.

Cut-Length Errors

Cutting jack studs too short

A short jack leaves the header unsupported.

Leaving gaps beneath the header

The header must bear fully on the jacks.

Installing jack studs without proper bearing

Cut square and seat tight on the plate.

Bearing and Load-Path Errors

Ignoring support beneath the bottom plate

The load path must continue below.

Replacing jacks with unapproved connectors

Only approved anchors where the code allows.

Using incorrect fastening

Follow the code schedule or plans.

Assuming an LVL header follows the sawn-lumber chart

LVL support is product specific.

Ignoring wind and lateral-load requirements

Wind raises the full-height stud count.

Jack Stud Inspection Checklist

Header and Stud Verification

Check the header size, plies and span against the plans, then confirm the jack and king stud counts at each end.

Practical field checks.
Inspection itemWhat to verify
Wall typeBearing or nonbearing
Code editionLocally adopted requirements
HeaderCorrect size, plies, grade and span
Jack studsRequired count at each end
King studsRequired full-height count
LumberCorrect dimensions and grade
Cut lengthFull bearing beneath the header
Load pathContinuous support below
FasteningCode or approved plan
ConnectorsApproved and correctly installed
Rough openingCorrect dimensions
Wind and bracingRequired framing details maintained

Fastening

Check nail type, number and placement against the code schedule or the plans and connector instructions.

Structural Support

Confirm continuous support beneath the jacks, down to the foundation or a supporting beam.

Jack Stud Chart Limitations and Safety

Code and Design Limitations

This chart does not independently establish header structural capacity, jack stud compression capacity, bearing adequacy, foundation or floor support adequacy, full-height stud requirements in all wind conditions, engineered header compatibility, seismic or high-wind compliance, or structural adequacy after wall alterations.

Altering a Bearing Wall

For bearing-wall modifications, follow approved structural plans and obtain qualified professional review where required. The adopted code, the plans and the engineer control.

Structural Alterations

Removing or shortening jack studs in a remodel can overload the header and the framing below. Do not remove them without a design.

Primary References

Jack Stud FAQs

Sizes and Counts

What is a jack stud?

A jack stud, also called a trimmer, is a shorter vertical stud directly under the end of a header. It runs from the top of the bottom plate to the header underside and carries the header reaction down.

Is a jack stud the same as a trimmer stud?

In U.S. wood framing, yes. The two terms are used for the same member. The IRC uses jack stud.

How many jack studs are needed for a door?

There is no single number. In the 2024 IRC tables, the count per header end is one, two or three, depending on header size, building width, loads and whether the wall is bearing. A nonbearing wall may not need a bearing-wall header at all.

How many jack studs are needed for a window?

The same tables apply as for doors. The count depends on the header and loads, not on the window size alone.

Does every header need two jack studs?

No. Many 2024 table entries list one jack per end, such as a (2) 2×6 header in a 12 ft wide building. Others list two or three.

When are double jack studs required?

When the applicable table lists NJ = 2 for the header, such as a (2) 2×10 header at 24 ft building width in the 30 psf roof and ceiling slice.

When are triple jack studs required?

When the table lists NJ = 3. Examples include a single-ply 2×12 header in a 36 ft wide building, or a (2) 2×12 header at 70 psf ground snow and 36 ft width.

Can a header rest on one jack stud?

Yes where the applicable table lists one jack stud per end. The header is permitted to be supported by an approved framing anchor in that case as well.

Can a header hanger replace a jack stud?

Only where the table lists one jack stud and the connector is an approved framing anchor attached to the full-height stud and header. The full-height stud count then follows the higher wind category.

What is the difference between a king stud and a jack stud?

The jack stud sits under the header and supports it. The king stud runs from bottom plate to top plate beside the opening.

Are king studs and jack studs counted separately?

Yes. Jack stud counts come from Tables R602.7(1) and R602.7(2). Full-height stud counts come from Table R602.7.5.

How long should a jack stud be?

It runs from the top of the bottom plate to the underside of the header. In the example with a 90 in. clear height and a 2×10 header, the cut length is 80-3/4 in.

How do you calculate jack stud length?

Subtract the bottom plate top elevation from the header underside elevation, or subtract the actual header depth from the clear height when the header sits directly under the top plates.

Are jack studs needed in nonbearing walls?

Load-bearing headers are not required in nonbearing walls. A single flat 2×4 can serve for openings up to 8 ft where the nailing surface above is within 24 in.

Do LVL headers require more jack studs?

They can. Engineered headers use the manufacturer’s bearing and support requirements, so do not apply the sawn-lumber table.

What supports the load beneath a jack stud?

The bottom plate and the floor framing, blocking, beam or foundation below it. The load path must be continuous.

Can jack studs be removed during remodeling?

Not without a design. Removing them from a bearing opening can overload the header and the support below.

Which IRC table gives the number of jack studs?

Table R602.7(1) for exterior bearing walls and Table R602.7(2) for interior bearing walls. Table R602.7.5 gives full-height stud counts.

Download Jack Stud Chart PDF

Use your browser’s print function to save this page as a PDF for jobsite binders and plan sets. The printed version hides interactive elements and keeps the tables.

Print-ready letter format2024 IRC jack stud tablesKing stud countsInstant browser PDF

Cite or Embed This Chart

Reference this jack stud chart on your own site or article. Copy the citation below and link back to this page.

<p>Jack Stud Chart via <a href="https://concretecalculate.com/jack-stud-chart/">ConcreteCalculate.com</a></p>