Door Rough Opening Chart – Standard Interior & Exterior Door Sizes

Door Rough Opening Chart: Interior & Exterior Sizes | ConcreteCalculate.com
Interior & Exterior Framing Reference

Door Rough Opening ChartStandard Interior & Exterior Door Sizes

Rough opening sizes for 24 to 36-inch doors, with manufacturer examples for exterior, double and pocket doors, plus how to measure and verify the opening.

Interior planning chartVerified manufacturer examplesFloor-datum guidanceUpdated October 2026

Quick Answer: There Is No Single Rough Opening Rule

  • Preliminary interior planning: slab width +2 in. and slab height +2-1/2 in., so a 30 x 80 door frames at about 32 x 82-1/2 in.
  • Published exterior examples are unit specific: a 36 x 80 Therma-Tru unit needs 38-1/2 x 82-1/2 in. in one sizing set and 38-1/4 x 82 in. in another.
  • Pocket doors use different math: Johnson 1500 Series width = 2 x door + 1 in. Always verify the exact unit before framing.

Door Rough Opening Chart

Common interior prehung door sizes with clearly labeled planning assumptions.

Use these dimensions for preliminary interior-door planning only. Before framing, verify the rough opening specified for the exact prehung door you will install.

Interior prehung door rough opening: preliminary planning dimensions
Nominal interior door slabIllustrative RO widthIllustrative RO height
18 x 80 in.20 in.82-1/2 in.
20 x 80 in.22 in.82-1/2 in.
24 x 80 in.26 in.82-1/2 in.
26 x 80 in.28 in.82-1/2 in.
28 x 80 in.30 in.82-1/2 in.
30 x 80 in.32 in.82-1/2 in.
32 x 80 in.34 in.82-1/2 in.
34 x 80 in.36 in.82-1/2 in.
36 x 80 in.38 in.82-1/2 in.

Values assume the stated +2 in. width and +2-1/2 in. height convention. Heights assume the unit’s specified floor datum. Metric: 1 in. = 25.4 mm.

Important chart assumptions

This is a trade-planning convention, not a building standard or a manufacturer table. Confirm the assembled-unit size, shim allowance and the manufacturer’s rough-opening requirement, and check the floor reference used for the height.

Where this chart does not apply

Do not use it for exterior entry units, fire-rated assemblies, pocket doors, bifolds or sliding doors without product-specific verification. It does not give code-required clear passage width.

Door Rough Opening Framing – Width, Height, Header, King Studs and Jack Studs
Wood-framed door rough opening showing header, king studs, jack studs, and measurement arrows indicating rough opening width between framing members and height from subfloor to header.

What Is a Door Rough Opening?

The framed opening that receives the door assembly.

The rough opening (RO) is the framed space that receives the door assembly. It is bounded by the jack (trimmer) studs, the underside of the header and the floor reference.

Width and height

RO width is measured between the framing faces that receive the unit. RO height is measured from the specified floor reference to the header underside.

Installation allowance

The RO is larger than the unit so the frame can be set plumb, level and square.

Shim space

The gap between the unit and the framing that you fill with shims. It is not a fixed dimension for every door.

Structure vs finish

Framing is structural. Casing, stops and finish floors are finish components added later.

For framing lumber terms such as nominal and actual stud sizes, see the Lumber Size Chart. For common wall-stud layout around an opening, see the Stud Spacing Chart.

Door Slab vs. Unit Size vs. Rough Opening

Four measurements that should never be swapped.

Four measurements are often confused.

Door slab

The moving panel only.

Prehung unit

The slab plus its assembled frame, as defined by the manufacturer.

Rough opening

The framed opening into which the unit is installed.

Finished opening

What remains after jambs, stops and finishes are installed.

36 x 80 exterior prehung door: nominal size, unit and rough opening (Therma-Tru size specification, Dec. 2010)
MeasurementSet 1 widthSet 1 heightSet 2 widthSet 2 height
Nominal door designation36 in.80 in.36 in.80 in.
Assembled unit37-5/8 in.82 in.37-1/2 in.81-1/2 in.
Manufacturer rough opening38-1/2 in.82-1/2 in.38-1/4 in.82 in.
RO minus unit7/8 in.1/2 in.3/4 in.1/2 in.

Set 1 and Set 2 are two sizing sets in the same manufacturer document. The RO-minus-unit row is an overall allowance and does not mean equal gaps at every edge. Brickmould-to-brickmould dimensions add 2-1/2 in. to width and 1-1/4 in. to height in that document, so trim size is not rough-opening size.

Door slab, assembled prehung unit and rough openingFront elevation of a prehung swing door in a framed wall opening showing three nested boundaries: the door slab width D, the assembled unit width U and the framed rough opening width RO. Labels identify the hinge jamb, strike jamb, header framing, shim space and door slab. No numerical jamb or shim dimensions are implied.Door slabHinge jambShim spaceStrike jambHeader framingRough opening(framed)D: Door slab widthU: Assembled unit widthRO: Framed rough-opening widthSlab size is not assembled unit size, and neither is the rough opening.Schematic only: no universal jamb or shim dimensions are implied.Orange dashed line = framed rough opening (between the jack studs).

Figure 1. Door slab, assembled unit and rough opening. Schematic, with no universal jamb or shim dimensions.

Standard Interior Door Rough Opening Chart

Trade size names, slab sizes and illustrative openings.

Interior doors are often called by feet and inches (2-6 x 6-8 means 30 x 80 in.). The planning convention is RO = slab width + 2 in. and RO = slab height + 2-1/2 in.

Standard interior door sizes: trade name, slab and illustrative rough opening
Door size name (ft-in)Nominal slabIllustrative RO (in.)Illustrative RO (mm)
1-6 x 6-818 x 80 in.20 x 82-1/2 in.508 x 2096 mm
1-8 x 6-820 x 80 in.22 x 82-1/2 in.559 x 2096 mm
2-0 x 6-824 x 80 in.26 x 82-1/2 in.660 x 2096 mm
2-2 x 6-826 x 80 in.28 x 82-1/2 in.711 x 2096 mm
2-4 x 6-828 x 80 in.30 x 82-1/2 in.762 x 2096 mm
2-6 x 6-830 x 80 in.32 x 82-1/2 in.813 x 2096 mm
2-8 x 6-832 x 80 in.34 x 82-1/2 in.864 x 2096 mm
2-10 x 6-834 x 80 in.36 x 82-1/2 in.914 x 2096 mm
3-0 x 6-836 x 80 in.38 x 82-1/2 in.965 x 2096 mm

Illustrative figures, not a manufacturer-issued universal table. Confirm the actual prehung unit before framing.

Rough Openings for Common Door Widths

24, 28, 30, 32 and 36-inch doors.

24-Inch Door

Nominal 24 x 80 in. planning RO: 26 x 82-1/2 in. The jamb, head clearance and floor reference can change the actual requirement.

28-Inch Door

Nominal 28 x 80 in. planning RO: 30 x 82-1/2 in. Check the exact prehung frame specification.

30-Inch Door

Nominal 30 x 80 in. planning RO: 32 x 82-1/2 in. A 32-inch framed opening is not a 32-inch clear passage.

32-Inch Door

Nominal 32 x 80 in. planning RO: 34 x 82-1/2 in. Nominal width alone does not prove any required clear opening.

36-Inch Door

The answer depends on the door type. Compare three contexts.

36 x 80 door: three different dimensional contexts
Door exampleRO widthRO height
Illustrative interior 36 x 8038 in.82-1/2 in.
Therma-Tru exterior 36 x 80, Set 138-1/2 in.82-1/2 in.
Therma-Tru exterior 36 x 80, Set 2 (U-1 convention)38-1/4 in.82 in.

The two exterior rows are different sizing sets in one manufacturer’s document, not conflicting measurements for one door. That is why there is no single correct answer for a 36-inch door.

Rough Openings for 84-Inch and 96-Inch Doors

Taller doors need their own verification.

The interior height convention gives 84 + 2.5 = 86.5 in. and 96 + 2.5 = 98.5 in. These are planning examples only.

Taller doors: illustrative interior heights versus published exterior examples
Door heightInterior planning RO heightTherma-Tru Set 1 (36 wide)Therma-Tru Set 2 (36 wide)
80 in. (6-8)82-1/2 in.38-1/2 x 82-1/2 in.38-1/4 x 82 in.
84 in. (7-0)86-1/2 in.Not in the data reviewedNot in the data reviewed
96 in. (8-0)98-1/2 in.38-1/2 x 98-1/2 in.38-1/4 x 98 in.

Masonite lists 82.5 in. and 98.5 in. as common exterior rough-opening heights while stressing that sizes vary. Do not assume every 96-inch exterior door uses a 98-1/2 in. opening; the second Therma-Tru set above uses 98 in. for a 96-inch door.

Exterior Door Rough Opening Chart

Manufacturer examples, not universal values.

Exterior prehung units include jambs, sills and thresholds, so their rough openings come from the manufacturer’s unit table. These are identified examples from one document, not universal values.

Exterior prehung single door rough openings (Therma-Tru size specification, Dec. 2010; inches)
Nominal doorSet 1 unitSet 1 rough openingSet 2 unitSet 2 rough opening
32 x 8033-5/8 x 8234-1/2 x 82-1/233-1/2 x 81-1/234-1/4 x 82
36 x 8037-5/8 x 8238-1/2 x 82-1/237-1/2 x 81-1/238-1/4 x 82
42 x 8043-5/8 x 8244-1/2 x 82-1/2––
36 x 9637-5/8 x 9838-1/2 x 98-1/237-1/2 x 97-1/238-1/4 x 98

The document says to deduct 1 in. from the unit height for outswing doors, and brickmould-to-brickmould measurements add 2-1/2 in. to width and 1-1/4 in. to height. This is a December 2010 document; confirm the selected current product still uses these dimensions.

36 by 80 inch exterior prehung door: unit versus rough openingFront elevation of a 36 by 80 inch nominal exterior prehung door from a published Therma-Tru size specification. The actual unit is 37-5/8 by 82 inches and the rough opening is 38-1/2 by 82-1/2 inches. The total width difference is 0.875 inch and the total height difference is 0.5 inch, shown at near scale.36 x 80 in.nominal doorManufacturer-specific exampleTherma-Tru size specification (Dec. 2010)Nominal door: 36 x 80 in.Actual unit: 37-5/8 x 82 in.Rough opening: 38-1/2 x 82-1/2 in.Width: 38.5 – 37.625 = 0.875 inHeight: 82.5 – 82 = 0.5 inThese are total differences, not equal gapsat every edge of the frame.Unit and rough opening are drawn near scale(4.8 px per inch), so the gap looks small.Do not apply these values to other doorsor sizing series.Unit 37-5/8 inRough opening 38-1/2 inRO height 82-1/2 inUnit height 82 in

Figure 2. A 36 x 80 exterior unit and its rough opening from the Set 1 example, drawn near scale.

What changes the exterior opening

  • Prehung jambs and brickmould (trim is not part of the rough opening).
  • Thresholds, sill pans and flashing thickness.
  • Inswing versus outswing configuration.
  • Product series and the manufacturer’s sizing convention.

Other makers use different allowances. The covered Andersen entry doors need an opening 1/2 in. larger than the unit in both width and height, with allowance for flashing thickness. Andersen’s 200 and 400 Series product guide lists minimum openings of door width +3/4 in. and door height +1/2 in. for its single- and two-panel patio doors. Masonite lists 38.5 in. and 34.5 in. as common exterior widths.

Prehung exterior door installed in a wood-framed rough opening, showing example dimensions of 38-1/2 inches wide and 82-1/2 inches high, with jamb, sill, header, and installation clearance labeled.
Prehung exterior door installation showing example rough opening dimensions of 38-1/2 inches wide and 82-1/2 inches high, along with the door jamb, sill, header, and clearance required for proper installation.

Double Door and French Door Rough Openings

Frame to the unit-specific size, never to a doubled number.

A double-door opening is not twice a single-door opening. Two slabs, a combined jamb assembly, meeting stiles, astragals, sidelites and transoms all change the unit dimensions.

Double and French/patio door examples (Therma-Tru size specification, Dec. 2010)
UnitActual unit sizeRough opening
32 x 80 pre-hung double, Set 166-9/16 x 8267-1/4 x 82-1/2
36 x 80 pre-hung double, Set 174-9/16 x 8275-1/4 x 82-1/2
36 x 80 pre-hung double, Set 274-1/4 x 81-1/274-3/4 x 82
5-0 replacement double patio/French unit59-1/2 x 79-1/260 x 80
6-0 replacement double patio/French unit71-1/2 x 79-1/272 x 80

Identified examples only. Replacement patio/French units are jamb-to-jamb. Frame to your unit’s rough-opening table; Andersen’s Frenchwood guidance also tells installers to use the unit-specific dimensions.

Pocket Door Rough Opening Chart

Why pocket doors cannot use the swing-door rule.

A pocket door frame includes the pocket into which the door slides, so the framed width is about twice the door width.

Pocket door rough opening: Johnson Hardware 1500 Series frame
Nominal door slabManufacturer RO widthManufacturer RO height
24 x 80 in.49 in.84-1/2 in.
28 x 80 in.57 in.84-1/2 in.
30 x 80 in.61 in.84-1/2 in.
32 x 80 in.65 in.84-1/2 in.
36 x 80 in.73 in.84-1/2 in.

Johnson 1500 Series formula

ROw = 2Dw + 1 in.    ROh = Dh + 4-1/2 in.

Check: for a 30 x 80 door, 2(30) + 1 = 61 in. and 80 + 4.5 = 84.5 in., which matches the manufacturer’s 61 x 84-1/2 in. opening.

Applies only to this frame system. Other pocket-door hardware uses different dimensions; the same Johnson sheet sets the header-mounting height at 80-3/4 in. above the finish floor or 81-1/2 in. above the subfloor.

Bifold Door Rough Opening

Verify the hardware system first.

Bifold doors are sized by the finished opening and hardware, not by the swing-door +2 in. convention. Nominal bifold size, specified finished opening, framed rough opening and track and pivot hardware requirements are different things.

Use the manufacturer’s installation guide for the exact opening. Do not apply the swing-door convention to bifold doors.

Sliding Patio Door Rough Opening

Complete assembly dimensions control.

Sliding patio doors are ordered by complete unit size or manufacturer configuration, not by the size of one sliding panel.

  • Sill, flashing and installation flange affect the opening.
  • Masonry openings have their own requirements.
  • Frame to the unit-specific rough-opening table in the installation guide.

This section is kept short on purpose to avoid duplicating a future patio-door chart.

How to Calculate a Door Rough Opening

Two distinct methods, used for different purposes.

Method A: preliminary interior planning

ROw ≈ Dw + Aw    ROh ≈ Dh + Ah
  • Dw, Dh = nominal slab width and height (in.)
  • Aw = 2 in., Ah = 2-1/2 in. (illustrative convention)

Method B: actual prehung unit

ROw = Uw + Cw    ROh = Uh + Ch
  • Uw, Uh = actual assembled-unit width and height (in.)
  • Cw, Ch = total width and height allowance specified by the manufacturer

Cw and Ch must come from the manufacturer

They are not universal. Examples in this page range from 1/2 in. total (Andersen entry doors) to 7/8 in. wide (Therma-Tru Set 1).

Worked Door Rough Opening Examples

One interior planning example and one manufacturer example.

1

30 x 80-Inch Interior Door (Method A)

Given: Nominal slab 30 x 80 in.; convention +2 in. wide, +2-1/2 in. tall.
1
RO width = 30 + 2 = 32 in.
2
RO height = 80 + 2.5 = 82.5 in.
Result: 32 x 82-1/2 in. (planning)

What it means: The exact RO remains subject to the prehung door’s specification and floor-height reference.

2

36 x 80-Inch Exterior Door (Method B)

Given: Therma-Tru Set 1 example: actual unit 37-5/8 x 82 in.; specified RO 38-1/2 x 82-1/2 in.
1
Cw = 38.5 – 37.625 = 0.875 in.
2
Ch = 82.5 – 82 = 0.5 in.
3
For Set 2: Cw = 38.25 – 37.5 = 0.75 in. and Ch = 82 – 81.5 = 0.5 in.
Result: Cw = 0.875 in., Ch = 0.5 in. (Set 1)

What it means: The allowances are total differences between the unit and the rough opening, not necessarily equal gaps on every side.

Rough Opening Width: Jambs and Shims

Where the extra width goes.

The assembled unit width includes the frame, so the opening has to allow for the jambs plus installation clearance.

  • Hinge jamb and strike jamb: both are part of the unit width.
  • Frame thickness: common side jamb depths are 4-9/16, 5-1/4 and 6-9/16 in., depending on wall thickness, but not every door matches.
  • Shim allowance: the gap you fill to plumb the frame; it is small and product specific.
  • Installation tolerances: out-of-plumb framing consumes the allowance.

Do not assume all jambs have identical dimensions. Use the unit’s own frame size.

Rough Opening Height: Subfloor vs. Finished Floor

Measure from the right floor level.

Height depends on which floor reference the product uses. Subfloor, finished floor, carpet, tile, threshold and sill support all change the number.

Masonite measures interior replacement openings from the finished floor or carpet to the bottom of the header, and exterior replacement openings from the subfloor.

Coordinate conversion (illustrative)

H1 = H2 + tfloor
  • H1 = subfloor to header underside
  • H2 = finished floor to header underside
  • tfloor = finish floor thickness (3/4 in. here)
3

Finished-Floor to Subfloor Reference

Given: H2 = 82.5 in. (finished floor to header); floor finish = 3/4 in.
1
H1 = H2 + 0.75
2
H1 = 82.5 + 0.75 = 83.25 in.
Result: H1 = 83.25 in.

What it means: This is a coordinate conversion, not an instruction to add 3/4 in. to every rough opening. The Johnson Hardware pocket-door sheet shows the same 3/4 in. step (80-3/4 in. from the finish floor, 81-1/2 in. from the subfloor).

Rough opening height: subfloor versus finished floorVertical wall section through an interior door opening showing the header underside, side framing, door frame, door slab, finished floor and subfloor. H1 is measured from the subfloor to the header underside and H2 from the finished floor to the header underside. With an illustrative 3/4 inch finish floor, H1 equals H2 plus 0.75 inch. The drawing is not to scale.Structural headerDoor slabin door frameFinish floorSubfloorSide framingH2H1H2: finished floor to header undersideH1: subfloor to header undersideIllustrative finish-floor buildup = 3/4 in.H1 = H2 + 0.75 inExample: 82.5 + 0.75 = 83.25 inThe 3/4 in. is illustrative. The actual floor assembly and themanufacturer’s measurement datum must control. Not to scale.

Figure 3. Rough opening height from the subfloor (H1) versus the finished floor (H2). Not to scale.

How to Measure an Existing Door Rough Opening

Casing off, multiple readings, smallest value.

Expose the framing, measure at several points and record the smallest dimension.

  1. Measure width at the top, middle and bottom, from stud to stud.
  2. Measure height at more than one location, from the correct floor datum to the header.
  3. Identify the floor datum required by the replacement product.
  4. Record the smallest usable width and height (Masonite suggests the nearest 1/16 in.).
  5. Measure the existing unit separately; do not confuse trim-to-trim or slab dimensions with framing.
  6. Verify the replacement unit and its required rough opening.
Carpenter using a tape measure to check the width of an interior door rough opening between jack studs, with the header and king studs labeled.
A carpenter measures the rough opening width between the inside faces of the jack studs. The exposed framing identifies the header, king studs, and jack studs used in residential door construction.
Measuring and checking a door rough openingFront elevation of an exposed framed doorway showing three width measurements W1 top, W2 middle and W3 bottom, height measurements H1 and H2, two corner-to-corner diagonals D1 and D2, a level on the sill and plumb references at both sides. Record the smallest usable width and height and verify plumb, level and square.HeaderD1D2W1 (top)W2 (middle)W3 (bottom)H1H2Level (sill)PlumbreferencePlumbreferenceRecord the smallest usable width and height;verify plumb, level and square.W1 / W2 / W3: top, middle and bottom widthsH1 / H2: height measurements from the correct floor datumD1 / D2: diagonals (corner to corner)Equal diagonals alone do not prove the opening is plumb, level and correctly sized.

Figure 4. Width, height and diagonal measurements, plus level and plumb checks.

Checking for Square, Plumb and Level

What to verify before the unit goes in.

A rough opening can have the right dimensions and still be hard to install in.

  • Sill or floor line: level.
  • Side framing: plumb.
  • Header: level.
  • Diagonals: compare corner to corner.
  • Clearance: enough for the specified unit.

For one Andersen hinged patio door, the guide says an opening is square if the two diagonals are within 1/8 in. That is a requirement of that installation guide, not a universal framing-code tolerance, and equal diagonals alone do not prove plumb or level.

Door Rough Openings in Load-Bearing Walls

Structural checks before you enlarge an opening.

Widening or adding an opening in a load-bearing wall changes how loads reach the foundation.

  • The header must be sized for the span and loads (engineered options such as LVL appear in the LVL Span Chart).
  • Supporting studs and bearing at each end need checking.
  • Existing framing modifications need temporary support during alterations.

Adding 2 inches to a rough opening is not structurally harmless in a bearing wall. Check the applicable structural requirements first.

Door Rough Opening vs. Code-Required Clear Opening

Framing dimension versus installed clear passage.

Code-required clear opening is a different measurement from the rough opening.

The 2021 IRC, Section R311.2, requires at least one qualifying side-hinged egress door per dwelling unit with a clear width of at least 32 in. (measured between the face of the door and the stop, with the door open 90 degrees) and a clear height of at least 78 in. (from the top of the threshold to the bottom of the stop).

  • These dimensions are measured on the installed opening, not at the framing stage.
  • A nominal 32-inch slab will not provide a 32-inch clear opening once hung in a frame.
  • Other doors are not required to meet these minimums.
  • Accessibility rules are separate and may involve different codes, standards and measurement conditions.

Confirm the locally adopted code and any amendments.

Fire-Rated Door Rough Openings

Use the listing, not a generic formula.

Fire-rated doors are listed assemblies. They need listed frame and door components, approved installation methods, specified clearances and correct hardware.

Do not apply a generic rough-opening chart to a rated assembly without its listing and installation instructions. Door-to-frame clearance is not the same as rough-opening shim clearance.

What If the Rough Opening Is Too Large or Too Small?

Fix the framing, not the door.

  • Too large: the frame needs more shimming, blocking or added framing, and large gaps affect fastening and air sealing. Correct the framing instead of stacking shims.
  • Too small: the unit will not fit or cannot be set plumb and square. Trim or reframe the opening; do not force or cut the door frame.

Confirm the amount of allowance in the manufacturer’s instructions before correcting either condition.

Common Door Rough Opening Mistakes

Errors that cost a re-frame.

Using slab width as RO width

The RO must be larger than the unit.

Adding a generic allowance to a unit

The assembled unit already includes the jamb.

Using the interior rule on an exterior door

Exterior units have their own tables.

Measuring casing instead of framing

Casing hides the true opening.

Using the wrong floor datum

Subfloor and finished floor differ.

Ignoring flooring added later

It changes finished height.

Confusing brickmould with the RO

Trim width is not framing width.

Assuming all 36 x 80 exterior doors match

Sizing sets differ.

Applying swing-door math to pocket doors

Pocket frames use their own formula.

Doubling a single-door RO for French doors

Use the unit’s table.

Ignoring sill pan and flashing

They affect the opening.

Framing out of square

Check diagonals, plumb and level.

Assuming nominal width equals clear width

Clear width is measured when installed.

Changing bearing framing without checking

Structure may need design.

Ignoring the installation instructions

They control the final RO.

More framing references are in the Construction Charts hub.

Door Rough Opening FAQs

Short answers to common rough-opening questions.

Print This Door Rough Opening Chart

Use your browser to save this page as a PDF for a job-site binder or estimating folder. Interactive sections are hidden when printing.

Interior planning chartManufacturer examplesFormulas and worked examplesMeasuring checklist