Construction Charts

Stair Stringer Size Chart – Lumber Sizes, Throat Depth and Span

Stair Stringer Size Chart: 2×12, Span & Spacing | ConcreteCalculate.com
AWC DCA 6 & IRC Stair Reference

Stair Stringer Size ChartLumber Sizes, Throat Depth and Span

2 x 12 stringer dimensions, minimum throat depth, cut and solid stringer spans, spacing and counts, plus the geometry that sets stringer length.

Cut and solid stringersThroat depth formulaCount and length chartsUpdated October 2026

Quick Answer: Size, Throat, Span and Spacing Are Four Different Numbers

  • AWC DCA 6 (2015 IRC basis) requires nominal 2 x 12 minimum stringers for its prescriptive deck stairs; actual depth is 11-1/4 in.
  • Cut stringers need 5 in. minimum remaining throat, 6 ft maximum span and 18 in. o.c. maximum spacing. Solid stringers: 13 ft 3 in. span and 36 in. o.c. with the prescribed tread assembly.
  • Stringer geometry length is not the structural span, and these limits are not rules for every stair.

Stair Stringer Size Chart

Lumber, throat depth, span and spacing for cut and solid stringers.

These values come from the American Wood Council’s DCA 6, Prescriptive Residential Wood Deck Construction Guide, based on the 2015 IRC. They apply to that guide’s covered deck stairs.

Stair stringer size chart: AWC DCA 6 prescriptive residential wood-deck stairs
Stringer configurationMinimum nominal lumberCommon actual sizeRequired remaining throatMaximum prescribed spanMaximum prescribed spacing
Cut wood stringer2 x 121-1/2 x 11-1/4 in.5 in. minimum6 ft18 in. o.c.
Solid wood stringer2 x 121-1/2 x 11-1/4 in.Not applicable (no stair-step cutouts)13 ft 3 in.36 in. o.c., with the specified tread and ledger assembly

How to read the chart

  • The throat depth is measured after the notches are cut.
  • The span limits describe support spacing, not purchased lumber length.
  • Spacing depends on the prescribed tread and connection details. The 36 in. and 18 in. values are not interchangeable.
  • Metric: 11-1/4 in. = 285.8 mm, 5 in. = 127 mm, 6 ft = 1.83 m, 13 ft 3 in. = 4.04 m.

Scope and source

DCA 6 also says that for stairs wider than 36 in., a combination of cut and solid stringers may be used at a maximum of 18 in. on center, and that at least three cut stringers are required if only cut stringers are used. Composite, PVC, engineered-wood, steel and proprietary stairs need their own design or manufacturer specification. Confirm the locally adopted code.

No 2 x 10 row on purpose

The researched prescriptive detail requires 2 x 12. A smaller cut stringer needs a separately justified design, not an invented span value.

Notched 2×12 wood stair stringer showing 11-1/4-inch actual lumber depth, typical 10–11-inch tread run, 7-3/4-inch riser height, and remaining throat depth.
A notched 2×12 stair stringer illustrating tread run, riser height, and remaining throat depth. The diagram identifies the actual 11-1/4-inch lumber depth and references the 5-inch minimum throat depth specified in AWC DCA 6 for its prescriptive stair-stringer design.

What Size Lumber Should Stair Stringers Be?

Why the cited design uses 2 x 12.

In the cited DCA 6 design, every stringer is at least nominal 2 x 12. The extra depth is what leaves usable wood under the notches.

  • Actual depth: 11-1/4 in., not 12 in.
  • Cutout geometry: the notches remove wood from the top edge.
  • Remaining section: at least 5 in. for the cut-stringer detail.
  • Support span: 6 ft for cut and 13 ft 3 in. for solid.
  • Species and grade: DCA 6 design values assume No. 2 grade and wet service.
  • Treatment: exterior lumber is preservative treated or naturally durable, with cuts field treated.

Do not generalize the DCA 6 minimum to every staircase. Engineered, interior or commercial stairs follow other design rules.

Nominal vs. Actual Stair Stringer Dimensions

2 x 8, 2 x 10 and 2 x 12 compared.

Nominal sizes are trade names. Common surfaced lumber is smaller than its label.

Stair stringer lumber dimensions: nominal versus actual
Nominal lumberActual thicknessActual depthUse in this chart
2 x 81.50 in.7.25 in.Dimensional comparison only
2 x 101.50 in.9.25 in.Dimensional comparison only
2 x 121.50 in.11.25 in.Minimum nominal size in the cited DCA 6 design

The 2 x 8 and 2 x 10 rows are not approvals for cut stair stringers. Board depth alone does not establish adequacy after notching. See the Lumber Size Chart for the general explanation.

2 x 8 lumber

Actual size is about 1-1/2 x 7-1/4 in. (38 x 184 mm).

2 x 10 lumber

Actual size is about 1-1/2 x 9-1/4 in. (38 x 235 mm).

2 x 12 lumber

Actual size is about 1-1/2 x 11-1/4 in. (38 x 286 mm).

2 x 12 Stair Stringer Size and Requirements

What the cited design requires of the member.

The DCA 6 stair provisions place these requirements on a 2 x 12 stringer.

  • Size: nominal 2 x 12 minimum, actual 1-1/2 x 11-1/4 in.
  • Notching: cut stringers keep at least 5 in. of throat.
  • Span: 6 ft for cut stringers and 13 ft 3 in. for solid stringers, shown in Figure 28 of the guide.
  • Count: if only cut stringers are used, at least three.
  • Connections: the top attaches with a sloped joist hanger, and the bottom bears on a supported end.

If a stringer would span more than the limit, DCA 6 allows a 4×4 post that is notched and bolted with two 1/2 in. through-bolts, or an intermediate landing.

Can You Use a 2 x 10 for Stair Stringers?

Layout fit is not structural approval.

The cited DCA 6 design requires a minimum nominal 2 x 12. A 2 x 10 is not approved just because the layout appears to fit in its depth.

Idealized remaining depth: notch geometry versus board depth (7-3/4 in. rise, 10 in. run)
Nominal lumberActual depthNotch depthRemaining throatMeets 5 in.?
2 x 87.25 in.6.13 in.1.12 in.No
2 x 109.25 in.6.13 in.3.12 in.No
2 x 1211.25 in.6.13 in.5.12 in.Yes

Geometric illustration only, using the idealized notch model in the throat-depth section. It is not a structural check.

Three different situations

  • Conventional prescriptive deck stair: DCA 6 requires 2 x 12.
  • Independently engineered stair: a design professional can justify other members.
  • Proprietary manufactured system: follow the manufacturer’s design documents.

Cut vs. Solid Stair Stringers

Two constructions with different limits.

Cut stringer versus solid stringer
FeatureCut stringerSolid stringer
Basic configurationStair-step notches cut into the memberContinuous-depth member with separate tread supports
AWC DCA 6 minimum member2 x 122 x 12
Remaining throat5 in. minimumNo comparable stair-step throat cut
Prescribed maximum span6 ft13 ft 3 in.
Prescribed maximum spacing18 in. o.c.36 in. o.c.
Tread supportNotched horizontal seatsPrescribed ledgers or support system
Key limitationReduced effective section at notchesTread and ledger assembly must meet prescribed details

Cut stringers

The notched stair profile. The notches create the treads but reduce the effective section.

Solid stringers

An unnotched member with treads carried on separately attached supports.

An unnotched 2 x 12 does not automatically qualify as a 13 ft 3 in. stair stringer. The tread and ledger assembly and end supports must meet the prescribed details.

Stair Stringer Throat Depth Chart

Remaining wood under the notches.

What is throat depth?

The shortest effective distance between the bottom of a notch and the opposite edge of the stringer.

How to measure remaining depth

Measure perpendicular to the uncut lower edge at the controlling notch, not straight down.

Why excessive notching matters

Cutouts reduce the member’s effective section. Saw cuts that run past the inside corners weaken it further.

Remaining throat of a 2 x 12 (11.25 in.) for common rise and run (idealized model)
Unit riseUnit runNotch depth (in.)Remaining throat (in.)Versus 5 in. minimum
7 in.10 in.5.745.52Above
7-1/2 in.10 in.6.005.25Above
7-3/4 in.10 in.6.135.12Above
7 in.11 in.5.915.34Above
7-3/4 in.11 in.6.344.91Below

Idealized geometry for a straight-sided 2 x 12. It does not include saw overcuts, defects, end connections or unusual geometry. A throat below 5 in. falls outside the cited prescriptive detail and needs a redesign or an engineered check.

2 by 12 cut stair stringer: actual depth and minimum throatSide elevation of a notched 2 by 12 stair stringer with three notches. Nominal lumber 2 by 12 has an actual depth of 11-1/4 inches and thickness of 1-1/2 inches. The minimum remaining throat is 5 inches, measured perpendicular to the uncut lower edge from the inside notch corner. AWC DCA 6 prescriptive cut-stringer example.Horizontal tread seatVertical riser cutInside notch cornerRemaining throat5 in. minimum(about 5.1 in. here)Uncut lower edgeActual depth11-1/4 in.1-1/2 in.11-1/4End viewNominal 2 x 12 = actual 1-1/2 x 11-1/4 in.AWC DCA 6 prescriptive cut-stringer example.Throat is measured perpendicular to the uncut lower edge, not vertically.Drawn for 7-3/4 in. rise and 10 in. run; schematic, not a structural verification.

Figure 1. A notched 2 x 12 with the 5 in. minimum throat measured perpendicular to the uncut lower edge.

How Stair Rise and Run Affect Throat Depth

The notch formula and a worked 7-3/4 in. example.

Larger rise or run deepens the notch measured across the sloping board, so less wood remains.

Idealized notch geometry

dnotch = (r × g) / √(r2 + g2)    tremaining = D – dnotch
  • D = actual board depth (11.25 in. for a 2 x 12)
  • r = unit rise, g = horizontal notch run
  • dnotch = notch depth measured perpendicular to the sloped edge
1

7-3/4 in. Rise and 10 in. Run

Given: D = 11.25 in., r = 7.75 in., g = 10 in.
1
dnotch = 7.75(10) / √(7.752 + 102) = 77.5 / 12.65
2
dnotch = 6.13 in.
3
tremaining = 11.25 – 6.13 = 5.12 in.
Result: t = 5.12 in.

What it means: This agrees with the roughly 5.1 in. depth AWC discusses in the DCA 6 commentary for a 7.75:10 rise-to-run ratio.

A model, not a verification

The formula is an idealized right-angle notch in a straight-sided board. It does not replace inspecting the actual stringer or complying with the governing design.

Stair Stringer Span Chart

Cut and solid stringer support spans.

The span is the horizontal distance between the supports shown in the guide. AWC analyzes solid stringers as simple-span beams using the horizontal span, not the actual stringer length.

Stair stringer support span in the cited DCA 6 design
Stringer typeNominal lumberMaximum prescribed span
Cut stringer2 x 126 ft
Solid stringer2 x 1213 ft 3 in.

Cut stringer maximum span

The 6 ft limit reflects the notched section, remaining throat, support conditions, loading and connections. A 2 x 12 cut stringer is not good for 6 ft under every condition.

Solid stringer maximum span

The 13 ft 3 in. limit applies to the prescribed solid-stringer assembly: continuous member depth, tread ledgers, tread species and size, supports and connections.

Structural span versus board length

The span chart does not set the purchased board length, and it is not permission to build any 13 ft 3 in. stair without checking loads, connections and support geometry. Add an intermediate post or landing for a longer flight.

Cut versus solid stair stringer support spanTwo stair elevations with identical drawn geometry. Cut stringer, nominal 2 by 12: maximum prescribed support span 6 feet. Solid stringer, nominal 2 by 12: maximum prescribed support span 13 feet 3 inches. The span is the horizontal distance between supports. Limits apply to the identified AWC DCA 6 prescriptive assemblies only.CUT STRINGERTop supportBottombearingMaximum prescribed span: 6 ftSOLID STRINGERTop supportBottombearingMaximum prescribed span: 13 ft 3 in.Nominal lumber: 2 x 12Stair-step cutoutsNominal lumber: 2 x 12Continuous depth; treadson separate supportsSpan = horizontal distance between supports. Not to scale; same stair drawn twice.Limits belong to the AWC DCA 6 assemblies, not to every wood beam.

Figure 2. Cut and solid stringer span limits. The same stair is drawn twice; the limits belong to the AWC DCA 6 assemblies.

Stair Stringer Spacing Chart

Spacing values and the assemblies they belong to.

Four things are easy to confuse: stringer spacing, stair width, tread span and structural stringer span.

  • Cut stringers: 18 in. o.c. maximum for the specified cut-stringer and tread assembly (2 x 4 or 5/4 treads).
  • Solid stringers: 36 in. o.c. maximum for the prescribed solid-stringer, tread and ledger assembly.
  • Wider stairs: DCA 6 allows a combination of cut and solid stringers at 18 in. o.c. maximum for stairs wider than 36 in.

These spacing values are not interchangeable. The Deck Post Spacing Chart covers support posts for the deck, not stringer spacing.

Four notched wood deck stair stringers installed 16 inches on center, with metal connectors attaching the upper ends to the deck frame and lower ends to a concrete landing.
Residential deck stair framing with four cut stringers spaced 16 inches on center. Metal connectors secure the upper ends to the deck framing and the lower ends to a concrete landing, illustrating stringer spacing and support arrangements.

How Many Stair Stringers Do You Need?

The count formula and 36, 42 and 48 inch examples.

Stringer count

N = ⌈ W / Smax ⌉ + 1
  • W = distance between outer stringer centerlines (in.)
  • Smax = permitted maximum on-center spacing (in.)
  • N = preliminary number of stringers
Preliminary stringer count at 18 in. maximum spacing (cut stringers)
Outer stringer centerline distancePreliminary countActual uniform spacing
36 in.318 in.
42 in.414 in.
48 in.416 in.
60 in.515 in.
72 in.518 in.

The first column is the distance between outer stringer centerlines, not automatically the finished stair width. The formula assumes a straight flight and uniform layout and is a layout aid, not a structural design. DCA 6 requires at least three cut stringers.

Stringers for 36-, 42- and 48-inch layouts

  • 36 in. example: three stringers at 18 in.
  • 42 in. example: four stringers at 14 in.
  • 48 in. example: four stringers at 16 in.
Stair stringer spacing and count: four stringers at 16 inchesPlan view of a straight stair with four parallel cut stringers S1 to S4 supporting transverse treads. Outer stringer centerline distance 48 inches, three spaces of 16 inches on center. N equals ceiling of 48 over 18 plus 1 equals 4, an illustrative layout under an 18 inch maximum spacing assumption.Plan view: straight stair, treads span across the stringersS1S2S3S416 in.16 in.16 in.Outer centerline distance 48 in.N = ceil(48 / 18) + 1 = 3 + 1 = 4 stringersIllustrative layout under an 18 in. maximum spacing assumption.The 48 in. is the distance between outer stringer centerlines,not the finished clear stair width.

Figure 3. Four stringers at 16 in. on center across a 48 in. outer centerline distance.

Stair Stringer Spacing for Wood and Composite Treads

Tread material changes the layout.

Wood tread size requirements

Minimum tread size for cut and solid stringers (AWC DCA 6, Table 6)
Wood species groupCut-stringer treadSolid-stringer tread
Southern Pine2 x 4 or 5/42 x 8
Douglas Fir-Larch, Hem-Fir, SPF2 x 4 or 5/42 x 8 or 3 x 4
Redwood, Western Cedars, Ponderosa Pine, Red Pine2 x 4 or 5/42 x 10 or 3 x 4

Assumes a 300 lb concentrated load, L/288 deflection limit, No. 2 grade and wet service conditions. These are member sizes for the specified tread configurations, not necessarily the finished tread depth; a tread can be built from more than one board.

Composite tread support requirements

Composite and PVC stair treads must follow the exact manufacturer’s stair-tread support and fastening requirements. Do not apply the 18 in. wood-tread allowance to a composite product.

  • Use the exact product and its current installation guide.
  • Check stair-tread approval, maximum support spacing, fastening and nosing.
  • Scalloped and solid profiles can differ.

If a product requires 12 in. maximum spacing, recalculate with 12 in. (see the table below). For decking dimensions see the Deck Board Size Chart, and for decking quantities use the Decking Calculator.

If a tread product requires 12 in. maximum support spacing (illustrative)
Outer stringer centerline distanceCount at 12 in. maximum
36 in.4
42 in.5
48 in.5
60 in.6
72 in.7

Stair Stringer Rise and Run Dimensions

IRC limits and the terms used on this page.

Five terms drive the stringer layout.

  • Total rise: finished floor to finished floor.
  • Unit rise: one riser height.
  • Total run: horizontal distance of the flight.
  • Unit run: horizontal depth of one step.
  • Number of risers and runs: runs = risers – 1 in a simple straight flight.
2021 IRC stair dimensional reference (R311.7.5)
ItemReference value
Maximum riser height7-3/4 in.
Minimum tread depth10 in.
Maximum riser-height variation in a flight3/8 in.
Maximum tread-depth variation in a flight3/8 in.

Local code adoption and exceptions apply. The 10 in. tread depth is not automatically the horizontal notch run used on the stringer, because nosing and tread construction affect the finished geometry.

The full rise and run method belongs in the Stair Rise and Run Chart; this page only shows how those numbers affect the stringer.

TOOLS & EQUIPMENT

Equipment for Your Project

Affiliate disclosure: As an Amazon Associate, ConcreteCalculate earns from qualifying purchases. We may also earn a commission from other affiliate links at no additional cost to you.

How to Calculate Stair Stringer Length

Total rise, total run and the diagonal.

Geometric diagonal

H = N × r    R = (N – 1) × g    L = √(H2 + R2)
  • N = number of risers, r = unit rise, g = unit horizontal run
  • H = total rise, R = total horizontal run, L = geometric diagonal
2

Seven-Riser Stair

Given: N = 7, r = 7 in., g = 10 in.
1
H = 7(7) = 49 in.
2
R = (7 – 1)(10) = 60 in.
3
L = √(492 + 602) = √6001 = 77.47 in.
Result: L = 77.5 in. (about 6 ft 5-1/2 in.)

What it means: This is the theoretical diagonal. A 6 ft 6 in. blank will not necessarily accommodate the full uncut profile, end details and cutting allowance.

For an interactive version, use the Stair Calculator.

Seven-riser stair: rise, run and stringer lengthSide elevation of a straight seven-riser stair with 7 inch unit rise and 10 inch unit run. Total rise 49 inches, total horizontal run 60 inches (six runs), and geometric diagonal L equals the square root of 49 squared plus 60 squared, about 77.5 inches. The diagonal is geometry only, not a lumber blank length or a structural span.Lower landingUpper landingDiagonal L = 77.5 in.7 in.unit rise10 in. unit runTotal rise49 in.Total horizontal run 60 in. (6 runs)L = sqrt(49^2 + 60^2) = sqrt(6001) = 77.5 in. (about 6 ft 5-1/2 in.)7 risers, 6 horizontal runs. Geometry only: not a lumber blank length or a span approval.The run count depends on the actual landing and top-tread configuration.

Figure 4. Seven risers, six runs, total rise 49 in., total run 60 in. and a 77.5 in. diagonal.

Stair Stringer Length Chart by Number of Steps

Geometric diagonals for a 7 x 10 stair.

Geometric stringer diagonal by number of risers (7 in. rise, 10 in. run)
RisersTotal riseRunsTotal horizontal runGeometric diagonal
428 in.330 in.41.0 in.
535 in.440 in.53.2 in.
642 in.550 in.65.3 in.
749 in.660 in.77.5 in.
856 in.770 in.89.6 in.
963 in.880 in.101.8 in.
1070 in.990 in.114.0 in.

Assumes 7 in. risers, 10 in. runs, one fewer run than risers, a straight flight, the upper finished floor as the final surface, and no intermediate landing. These are geometric values, not allowable spans, and not stock-board lengths.

How to Choose a Stair Stringer Board Length

Why the diagonal is not the purchase length.

A stringer blank must cover more than the diagonal. Consider these.

  • Total geometry (rise and run).
  • Top connection and bottom bearing details.
  • End-cut requirements and a cutting margin.
  • Lumber quality and defects.
  • Transport and handling.

Do not buy a board by rounding the diagonal up to the next stock length. Use the Lumber Calculator for quantities after the layout is drawn.

Stair Stringer Layout and Cutting Dimensions

Framing-square layout and notch discipline.

Layout is repetition: mark the unit rise and run with a framing square, repeat the step positions, then establish the top plumb cut and bottom seat.

  • Account for the finished tread thickness and the landing elevations.
  • Keep saw cuts at the inside notch corners; overcuts beyond the corners weaken a cut stringer.
  • Check the remaining throat at the controlling notch before cutting the others.

This page is a size reference, not a step-by-step stair construction guide.

Bottom Riser Adjustment for Tread Thickness

Keeping finished risers equal.

When treads sit on top of the notches, the first riser may need an adjustment so every finished riser is the same.

3

Illustrative Bottom Riser

Given: Finished unit rise 7 in.; tread thickness 1 in. (illustrative).
1
Finished riser = 7 in. from the lower surface to the first tread top.
2
The tread adds its thickness on top of the seat, so the first seat is lower by 1 in.
3
Bottom stringer riser = 7 – 1 = 6 in.
Result: 6 in. bottom stringer riser (illustrative)

What it means: Do not universally remove exactly 1 in. The adjustment depends on tread thickness, top connection, landing height, finished-floor buildup and stair geometry.

Measure risers from finished surface to finished surface. IRC limits the variation in riser height within a flight to 3/8 in.

Stair Stringer Top Connection Requirements

Hangers, framing and load transfer.

Selecting a lumber size does not finish the design. The upper end must transfer loads to a supporting rim or header.

  • DCA 6 Figure 31 shows a sloped joist hanger with a minimum vertical (download) capacity of 625 lb for the illustrated attachment.
  • Use fasteners and connectors that are corrosion resistant (hot-dip galvanized or stainless steel) for treated lumber.
  • Blocking and the supporting member must carry the load.

That 625 lb value belongs to that detail; it is not a universal connector requirement.

Wood deck staircase showing a notched 2×12 stair stringer attached to the deck frame with a sloped metal hanger and supported at the bottom by a metal bracket on a concrete landing.
Deck stair stringer installation showing the upper connection to the deck frame using a sloped metal hanger and the lower support on a concrete landing. The illustration also identifies the stair treads, notched stringer, and supporting deck post.

Stair Stringer Bottom Support and Footings

Bearing at grade.

Stringers should be supported by bearing at the end where the stair meets grade.

  • DCA 6 attaches the stringers to the stair guard posts at the bottom, with posts bearing on footings.
  • A 2×4 bearing block helps avoid splitting at the stringer end, especially for cut stringers.
  • The default stair footing in the guide assumes a 40 psf live load and 10 psf dead load over an 18 in. width and half of the 13 ft 3 in. solid span, about 500 lb.
  • Moisture, settlement and anchorage matter; an unstable landing can invalidate suitable member dimensions.

Intermediate Stair Stringer Supports

Posts and landings that shorten the span.

When the span exceeds the limit, shorten it with intermediate support.

  • DCA 6 allows a 4×4 post, notched and bolted to the stringer with two 1/2 in. through-bolts with washers.
  • The post is centered on a 12 in. diameter or 10 in. square, 6 in. thick footing.
  • An intermediate landing may also shorten the span; if total stair height exceeds 12 ft, an intermediate landing is required and must be built as a non-ledger deck.

An arbitrary block under a stringer does not make a compliant support. For general post sizes see the Deck Post Size Chart.

Interior vs. Exterior Stair Stringer Sizes

Different design conditions.

Interior stairs

Dry-service conditions, finished assemblies and engineered framing are common. Architectural constraints and the adopted code drive the design.

Exterior deck stairs

Wet-service conditions apply. DCA 6 requires naturally durable or preservative-treated lumber (above-ground and ground-contact use categories), field treatment of cuts, and corrosion-resistant fasteners and connectors.

The DCA 6 chart is specifically relevant to its single-level residential wood-deck scope, not to every stair.

Engineered Wood and Steel Stair Stringers

Outside the 2 x 12 chart.

LVL and other engineered-wood stringers, steel channel stringers, fabricated steel plate stringers and proprietary stair systems cannot be sized from the 2 x 12 wood chart.

  • Require manufacturer design documentation or project-specific structural design.
  • Do not infer a universal LVL or steel size.

Stair Stringer Size vs. Stair Width

Width changes the count, not the span.

Stair width, stringer depth and stringer spacing are different things.

  • Member depth: the lumber and its remaining throat.
  • Stringer spacing: on-center layout.
  • Finished and clear stair width: what users walk on.
  • Tread projection: how far treads extend past the outer stringers.

For a 36 in. stair, DCA 6 requires at least three cut stringers. A wider stair usually needs more stringers or closer spacing, but that does not by itself change the allowable longitudinal span.

Common Stair Stringer Sizing Mistakes

Errors that make stringers fail inspection.

Assuming 2 x 12 is 12 in. deep

The actual depth is 11-1/4 in.

Using a 2 x 10 without verifying the design

Layout fit is not approval.

Cutting below the prescribed throat

Keep at least 5 in. for the cited detail.

Overcutting past notch corners

It weakens the stringer.

Confusing span with board length

They are different numbers.

Confusing spacing with tread depth

Spacing is on center.

Mixing cut and solid span limits

6 ft versus 13 ft 3 in.

Mixing cut and solid spacing

18 in. versus 36 in.

Assuming composite follows wood-tread rules

Check the product.

Ignoring tread species and grade

Table 6 depends on species.

Using the diagonal as structural approval

It is geometry only.

Forgetting the finished floor

Measure finished to finished.

Ignoring tread thickness at the bottom

The first riser may change.

Omitting top connection details

Hangers and blocking matter.

Setting stringers on unstable ground

Bearing must be stable.

Adding unengineered intermediate supports

Use the prescribed post and footing.

Using untreated exterior lumber

Treat or use durable species.

Assuming DCA 6 covers every stair

It is limited to its scope.

More framing references are in the Construction Charts hub.

Stair Stringer Size FAQs

Short answers to common stair stringer questions.

Print This Stair Stringer Size Chart

Use your browser to save this page as a PDF for a job-site binder or estimating folder. Interactive sections are hidden when printing.

Cut and solid stringer limitsThroat depth and geometryStringer count and lengthWorked examples

Cite or Embed This Chart

Reference this stair stringer size chart on your own site. Copy the code below and keep the link to this page.

<p>Stair Stringer Size Chart via <a href=”https://concretecalculate.com/stair-stringer-size-chart/”>ConcreteCalculate.com</a></p>