Construction Charts

OSB Thickness Chart – Standard Sizes, Span Ratings and Uses

OSB Thickness Chart: Walls, Roofs & Subfloors | ConcreteCalculate.com
DOC PS 2-18 & APA Reference

OSB Thickness ChartStandard Sizes, Span Ratings and Uses

Performance Categories from 3/8 to 1-1/8 in., decimal and metric sizes, Span Ratings, and wall, roof and subfloor guidance.

7 Performance CategoriesInches and millimetersSpan Rating tablesUpdated October 2026

Quick Answer: Thickness Is a Performance Category, Not the Whole Specification

  • APA lists seven common OSB Performance Categories: 3/8, 7/16, 15/32, 19/32, 23/32, 7/8 and 1-1/8 in. (23/32 = 0.71875 in. = 18.26 mm).
  • Structural OSB is selected by grade, Span Rating, Performance Category, bond classification and support spacing, not measured thickness alone.
  • The current standard is DOC PS 2-18; PS 2-25 is only a proposed revision as of October 2026.

OSB Thickness Chart

Performance Category, decimal and metric size.

These are the seven common OSB Performance Categories listed by APA, with decimal and millimeter conversions.

OSB thickness chart: Performance Category, decimal and metric size
OSB Performance CategoryFractional valueDecimal valueMetric equivalentCommon structural context
3/8 in.3/8 in.0.375 in.9.53 mmLighter Rated Sheathing (24/0); also a wall alternate
7/16 in.7/16 in.0.4375 in.11.11 mmCommon wall and roof Rated Sheathing (24/16)
15/32 in.15/32 in.0.46875 in.11.91 mmCommon Rated Sheathing (32/16)
19/32 in.19/32 in.0.59375 in.15.08 mmHeavier sheathing and floor applications (40/20)
23/32 in.23/32 in.0.71875 in.18.26 mmCommon subfloor and heavier sheathing (48/24)
7/8 in.7/8 in.0.875 in.22.23 mmLong-span and heavier floor applications (60/32)
1-1/8 in.1-1/8 in.1.125 in.28.58 mmHeavy-duty and longer-span floor applications

How to read the chart

  • Fractional thickness: the Performance Category, which building codes use as nominal thickness.
  • Decimal thickness: fraction converted to inches (numerator divided by denominator).
  • Metric equivalent: decimal inches times 25.4 mm.

Decimal and metric values are mathematical conversions. The fractions are Performance Categories, not a guarantee that every panel measures exactly that number with a caliper; PS 2 permits thickness tolerances.

OSB Performance Categories: proportional thickness comparisonSeven OSB panel edge profiles stacked vertically at the same scale, 80 pixels per inch. 3/8 equals 0.375 in or 9.53 mm; 7/16 equals 0.4375 in or 11.11 mm; 15/32 equals 0.46875 in or 11.91 mm; 19/32 equals 0.59375 in or 15.08 mm; 23/32 equals 0.71875 in or 18.26 mm; 7/8 equals 0.875 in or 22.23 mm; 1-1/8 equals 1.125 in or 28.58 mm. These are Performance Category and conversion values, not guaranteed field-measured thicknesses.OSB Performance Categories: proportional thickness comparison3/8 = 0.375 in. = 9.53 mm7/16 = 0.4375 in. = 11.11 mm15/32 = 0.46875 in. = 11.91 mm19/32 = 0.59375 in. = 15.08 mm23/32 = 0.71875 in. = 18.26 mm7/8 = 0.875 in. = 22.23 mm1-1/8 = 1.125 in. = 28.58 mmScale: 1 in.Performance Category and conversion values, not guaranteed field-measured thicknesses.

Figure 1. OSB Performance Categories drawn at the same scale.

What Is OSB?

A cross-oriented wood structural panel.

Oriented strand board (OSB) is a wood structural panel made from thin rectangular wood strands arranged in cross-oriented layers and bonded under heat and pressure with moisture-resistant adhesives.

APA identifies these common structural uses.

  • Wall sheathing and roof sheathing.
  • Subflooring and single-layer floors.
  • Webs of wood I-joists.
  • Other structural applications such as SIP facers.

Standard OSB Thicknesses

Seven common Performance Categories.

APA lists seven common Performance Categories for OSB: 3/8, 7/16, 15/32, 19/32, 23/32, 7/8 and 1-1/8 in. Specialty manufacturer thicknesses are outside this chart.

OSB thickness comparison showing 7/16-inch wall sheathing, 23/32-inch subfloor panels, and 1-1/8-inch heavy-duty OSB with APA span-rating stamps.
Common OSB thicknesses compared: 7/16 in. for wall sheathing, 23/32 in. commonly used for subfloors, and 1-1/8 in. for heavier-duty floor and roof applications.

OSB Performance Category vs. Actual Thickness

Why the fraction and the caliper can differ.

Performance Category is a designation tied to nominal thicknesses used in building codes. PS 2 defines it separately from measured thickness.

  • Performance Category: the code nominal thickness.
  • Decimal thickness designation: since 2008, panels also carry a decimal thickness on the label.
  • Tolerance: PS 2 allows the measured thickness to vary.

A caliper reading slightly different from the fraction does not by itself mean a panel is wrong. Use the grade stamp, not appearance, to identify a structural panel.

OSB Thickness Tolerances

What PS 2-18 permits.

PS 2-18 allows a tolerance of plus or minus 1/32 in. (0.8 mm) on Performance Categories of 13/16 in. and less, and plus or minus 5% on panels thicker than 13/16 in., unless a closer tolerance is set through qualification testing.

PS 2-18 thickness tolerance applied to each Performance Category (calculated window, inches)
Performance CategoryCategory (in.)PS 2-18 toleranceLower limit (in.)Upper limit (in.)
3/8 in.0.375±1/32 in. (±0.8 mm)0.34380.4062
7/16 in.0.4375±1/32 in. (±0.8 mm)0.40620.4688
15/32 in.0.46875±1/32 in. (±0.8 mm)0.43750.5000
19/32 in.0.59375±1/32 in. (±0.8 mm)0.56250.6250
23/32 in.0.71875±1/32 in. (±0.8 mm)0.68750.7500
7/8 in.0.875±5% (±0.0438 in.)0.83130.9187
1-1/8 in.1.125±5% (±0.0563 in.)1.06881.1812

The limits are calculated from the PS 2-18 tolerance. They are a tolerance window, not a manufacturing deduction. The standard also defines how thickness is measured.

OSB is not always 1/32 in. thinner than its label

The tolerance runs both ways. A 7/16 panel can measure from 0.4063 to 0.4688 in. and still be within PS 2-18. Do not create a rule that actual thickness equals nominal minus 1/32 in.

OSB Thickness in Inches and Millimeters

Converting Performance Categories.

Fraction, decimal and millimeters

t = n / d    tmm = tin × 25.4
1

23/32 OSB

Given: n = 23, d = 32.
1
t = 23 / 32 = 0.71875 in.
2
tmm = 0.71875 × 25.4 = 18.256 mm
3
Rounded: 18.26 mm.
Result: 0.71875 in. = 18.26 mm

What it means: This is a mathematical conversion. U.S. 23/32 OSB is not an exact 18 mm metric panel.

1 in. = 25.4 mm exactly. Do not treat a U.S. Performance Category as an independently standardized metric product.

What Does OSB Span Rating Mean?

24/16, 32/16, 40/20 and 48/24 explained.

Span Ratings identify the maximum recommended center-to-center spacing of supports for OSB used in code-conforming construction. Ratings appear in the APA trademark.

  • Rated Sheathing shows two numbers separated by a slash, such as 32/16.
  • The first number is the roof support spacing component.
  • The second number is the subfloor support spacing component.

A 32/16 panel may be used over roof supports up to 32 in. o.c. or floor supports up to 16 in. o.c., under the applicable rated conditions.

24/16, 32/16, 40/20 and 48/24

24/16 is rated 24 in. for roofs and 16 in. for floors, 32/16 is 32 and 16, 40/20 is 40 and 20, and 48/24 is 48 and 24. Wall-only panels are marked Wall-16 or Wall-24.

How to read an OSB Span Rating on a panel stampAn original educational diagram of a panel stamp reading RATED SHEATHING, 32 slash 16, 15/32 CATEGORY, EXPOSURE 1, PS 2-18. The first number 32 is the maximum rated roof support spacing component, the second number 16 is the maximum rated subfloor support spacing component, 15/32 is the Performance Category, Exposure 1 is the bond classification and PS 2-18 is the product standard.Simulated panel stamp (original educational diagram)RATED SHEATHING32/1615/32 CATEGORYEXPOSURE 1PS 2-1832: maximum rated roof supportspacing component (in. o.c.)16: maximum rated subfloor supportspacing component (in. o.c.)15/32: Performance CategoryExposure 1: bond classificationPS 2-18: product standardRated Sheathing: roof component / subfloor component32/16 means roof supports up to 32 in. o.c. and floor supports up to 16 in. o.c.under the applicable rated conditions. It is not 32 x 16 in. of panel size.Illustrative layout; real APA stamps differ and also show grade, mill and other marks.

Figure 2. Reading an OSB Span Rating on a simulated stamp.

OSB Thickness vs. Span Rating

The biggest misconception, corrected.

Thickness and Span Rating are related but not interchangeable. The panel stamp, not the measured thickness, identifies the rating.

OSB Rated Sheathing: Span Rating, thickness and spans (IRC Table R503.2.1.1(1))
Span RatingMinimum nominal thicknessRoof span with edge supportRoof span without edge supportSubfloor span
24/03/8 in.24 in.20 in.Not rated (0)
24/167/16 in.24 in.24 in.16 in.
32/1615/32 or 1/2 in.32 in.28 in.16 in.
40/2019/32 or 5/8 in.40 in.32 in.20 in.
48/2423/32 or 3/4 in.48 in.36 in.24 in.
60/327/8 in.60 in.48 in.32 in.

Values are from IRC Table R503.2.1.1(1) as published in the 2018 and 2021 IRC; other conditions in the table apply, and 16/0 and 20/0 ratings also exist. Check the edition your jurisdiction has adopted.

15/32 OSB does not always span 32 inches

Application, panel orientation, loading, edge support, the table conditions and the actual panel Span Rating all matter. A given Performance Category can appear in more than one rated construction.

How to Read an OSB Panel Stamp

The stamp is the specification.

The APA trademark identifies the panel and its intended use.

  • Panel grade: for example Rated Sheathing, Structural I Rated Sheathing or Rated Sturd-I-Floor.
  • Span Rating: such as 32/16, Wall-24 or 24 oc.
  • Performance Category: the nominal thickness used by codes.
  • Bond classification: Exposure 1 or Exterior.
  • Standard: PS 2-18 or APA PRP-108.
  • Mill and quality information.

Panels also carry a decimal thickness designation for packaging and labeling rules. Never use an unstamped panel based only on measured thickness.

Labeled APA OSB panel stamp showing 23/32-inch thickness, 24/16 span rating, tongue-and-groove edge, Exposure 1 bond classification, PS 2-18 standard, and Structural I grade.
Example of how to read an APA-rated OSB panel stamp, including thickness, span rating, T&G edge profile, Exposure 1 classification, product standard, and panel grade.

OSB Thickness for Wall Sheathing

Stud spacing, wind and bracing control.

Wall sheathing depends on stud spacing, wind pressure, fastening, bracing method and local code, not thickness alone.

  • Wall-only panels: marked Wall-16 or Wall-24 for maximum stud spacing; they may be installed with either axis across studs.
  • Rated Sheathing: panels with a roof rating of 24 or greater may be used on studs at 24 in. o.c.
  • Alternates: IRC allows Wall-16 or Wall-24 as an alternate to 24/0.

Examples from IRC Table R602.3(3) (2024): 24/0 at 3/8 in. nominal for 16 in. stud spacing, and 24/16 at 7/16 in. for 16 or 24 in. stud spacing, under the table’s wind and fastening conditions. See the Stud Spacing Chart for stud layout.

7/16 OSB for wall sheathing

7/16 in. is 0.4375 in. (11.11 mm) and is a common Rated Sheathing thickness, often associated with 24/16. Wall suitability depends on the stamp and the code conditions, so do not call it the standard wall thickness everywhere.

Wind and bracing considerations

Wind design and braced-wall requirements control. Do not turn the table into “3/8 OSB is always enough for walls.”

OSB Thickness for Roof Sheathing

Span Rating first, thickness second.

Choose roof OSB by Span Rating and rafter or truss spacing first, then by thickness. Roof loads, snow and wind, the roofing manufacturer’s requirements and local code also apply.

7/16 OSB

The 7/16 category corresponds to 24/16 Rated Sheathing in the IRC table. Whether it suits a roof depends on the stamp, spacing, loading, edge support and code.

15/32 OSB

15/32 = 0.46875 in. = 11.91 mm and corresponds to 32/16. It is not “better” in every case; compare ratings, not just fractions.

19/32 and 23/32 OSB

19/32 corresponds to 40/20 and 23/32 to 48/24. Thicker, higher-rated panels suit wider framing or higher stiffness needs, but thickness alone does not give a load rating.

For a cross-material view, see the Roof Sheathing Thickness Chart.

OSB Roof Sheathing Span Chart

Edge support changes the allowed span.

These are rating relationships, not blanket instructions to space rafters or trusses at those values.

OSB roof sheathing thickness and Span Rating chart
Performance CategoryCommon Span RatingRated roof componentRoof span with edge supportRoof span without edge support
3/824/024 in.24 in.20 in.
7/1624/1624 in.24 in.24 in.
15/3232/1632 in.32 in.28 in.
19/3240/2040 in.40 in.32 in.
23/3248/2448 in.48 in.36 in.
7/860/3260 in.60 in.48 in.

IRC Table R503.2.1.1(1) gives different roof spans with and without edge support under its stated conditions. For 48/24 the span is 48 in. with edge support and 36 in. without.

Edge support means lumber blocking, panel edge clips, tongue-and-groove edges or other approved support. Rafter and truss design belongs to the Roof Rafter Span Chart.

OSB Thickness for Subfloor

Joist spacing, finish and stiffness.

Subfloor choice depends on joist spacing, the finished floor, edge treatment, blocking, gluing and stiffness. APA distinguishes Rated Sheathing used as a subfloor from Rated Sturd-I-Floor, a combination subfloor-underlayment.

  • Tongue-and-groove edges or blocking support unsupported edges.
  • Glue-nailed systems increase stiffness and reduce squeaks.
  • Code spans are not the same as best-practice floor stiffness.

For joist spans see the Floor Joist Span Chart and the Joist Span Chart, or use the Floor Joist Calculator.

Keep two things separate: the minimum rated relationship in the code, and APA’s more conservative guidance for floor stiffness.

Code span-rating reference: representative OSB subfloor relationships (IRC Table R503.2.1.1(1))
Support spacingRepresentative minimum Span RatingRepresentative Performance Category
16 in. o.c.24/16 or 32/167/16 or 15/32
19.2 to 20 in. o.c.40/2019/32
24 in. o.c.48/2423/32
32 in. o.c.60/327/8
APA floor-performance guidance example: OSB subfloor under hardwood flooring (APA, 2025)
Joist spacingMinimum subfloor Performance CategoryMinimum Span Rating
16 in. or less23/32 OSB40/20 or 1F20 oc
More than 16 to 19.2 in.23/32 OSB48/24 or 1F24 oc
More than 19.2 to 24 in.7/8 OSB60/32 or 1F32 oc

The first table is a code/Span Rating reference. The second is a floor-performance example for hardwood-floor systems, not a universal code mandate.

OSB Subfloor Thickness for 16-Inch Joists

Code minimums versus floor performance.

Code relationships allow 24/16 (7/16 in.) or 32/16 (15/32 in.) at 16 in. APA’s 2025 guidance for a hardwood-floor system recommends 23/32 OSB at 16 in. or less, with a 40/20 or 1F20 oc rating. Both are correct; they answer different questions.

APA recommends this higher level despite thinner panels meeting some code-rated sheathing relationships.

OSB Subfloor Thickness for 19.2-Inch Joists

APA recommends 23/32 and a 48/24 rating.

For joists above 16 and up to 19.2 in., APA’s cited hardwood-floor guidance gives 23/32 OSB with a minimum 48/24 or 1F24 oc rating. This is floor-performance guidance, not a code mandate for every finish. The code table shows 40/20 (19/32) for roughly 19.2 to 20 in.

OSB Subfloor Thickness for 24-Inch Joists

APA recommends 7/8 and a 60/32 rating.

For joists above 19.2 and up to 24 in., APA’s cited guidance gives 7/8 OSB with a minimum 60/32 or 1F32 oc rating in the hardwood-floor context. Compare that with the 48/24 (23/32) code relationship without merging the two purposes.

Rated Sheathing vs. Rated Sturd-I-Floor

Two rating systems.

Rated Sheathing versus Rated Sturd-I-Floor
FeatureRated SheathingRated Sturd-I-Floor
Main useWall, roof and subfloor sheathingSingle-layer floor
Rating styleTwo numbers, e.g. 32/16One floor rating, e.g. 24 oc
First numberRoof spacingNot applicable
Second numberSubfloor spacingNot applicable
Floor ratingSecondary applicationPrimary application
Minimum Performance CategorySee span rating table19/32
Floor ratings madeNot applicable16, 20, 24, 32 and 48 oc

Sturd-I-Floor is a combination subfloor-underlayment designed to go under carpet and pad, and is typically tongue-and-groove. A floor rating of 20 oc corresponds to a 19.2 in. end-use span.

APA Rated Sheathing versus Rated Sturd-I-FloorTwo generic panel stamps. Rated Sheathing 48 slash 24: 48 is the roof rating and 24 is the subfloor rating, shown with a square-edge panel. Rated Sturd-I-Floor 24 oc: a single number that is the floor joist spacing rating, shown with tongue-and-groove floor edges. Original generic graphics, not APA artwork.APA Rated SheathingRATED SHEATHING48/2415/32 CATEGORY | PS 2-1848 = roof rating (in. o.c.)24 = subfloor rating (in. o.c.)Square edges (T&G only if marked)APA Rated Sturd-I-FloorSTURD-I-FLOOR24 oc19/32 CATEGORY MIN. | PS 2-1824 = floor joist spacing rating(single number, in. o.c.)Tongue-and-groove floor edgeTwo numbers (48/24) rate roof and subfloor. One number (24 oc) rates a single floor.Do not treat the two systems as interchangeable.Sturd-I-Floor has a minimum Performance Category of 19/32 and ratings of 16, 20, 24, 32 and 48 oc.A floor rating of 20 corresponds to a 19.2 in. end-use span.Original generic stamps, not APA artwork. Not to scale.

Figure 3. Two-number sheathing ratings versus a single-number floor rating.

OSB Strength Axis and Panel Orientation

Across the supports.

Rated Sheathing Span Ratings assume the panel strength axis, normally the long panel dimension unless marked otherwise, runs across the supports.

  • For roofs and floors, place the strength axis perpendicular to rafters, trusses or joists.
  • Wall-only panels (Wall-16, Wall-24) are tested with the secondary axis across supports and may be installed either way.
OSB strength axis and support directionPlan view of a 4 by 8 foot OSB panel over five joists at 24 inches on center. The long panel dimension, which is the strength axis, runs across the joists. Panel ends are supported on joists and the long edges may be tongue and groove. Rated roof and floor spans assume the strength axis is across supports unless otherwise specified.Optional tongue-and-groove long edgeOptional tongue-and-groove long edgeStrength axis (long panel direction)JoistJoistJoists run perpendicular to the strength axis24 in. o.c.24 in. o.c.24 in. o.c.24 in. o.c.Panel end on joistPanel end on joistRated roof/floor spans assume the strength axis is across supports unless otherwise specified.Wall-only panels (Wall-16, Wall-24) may be installed either way. Schematic; 24 in. o.c. is an example.

Figure 4. Strength axis runs across the joists.

Do not say “always install OSB horizontally”; walls differ from floors and roofs.

OSB subfloor panels installed over floor joists with 16-inch on-center spacing, staggered panel joints, and the panel strength axis perpendicular to the joists.
OSB subfloor installation showing 23/32-inch panels over 16-inch on-center floor joists, with staggered joints and the panel strength axis running perpendicular to the joists.

OSB Edge Support and Tongue-and-Groove Panels

Why edges matter.

Some roof spans require edge support to reach the rated span. Approved edge support includes:

  • Lumber blocking.
  • Panel edge clips (one midway between supports, or two equally spaced when the span is 48 in.).
  • Tongue-and-groove panel edges.
  • Other approved edge support.

Unsupported edges can change allowable roof spans and floor behavior. Floor panels with unsupported edges generally need tongue-and-groove edges or blocking unless an approved underlayment or finish floor is used.

Standard OSB Sheet Sizes

4 x 8, 4 x 9 and 4 x 10 ft.

APA lists 4 x 8, 4 x 9 and 4 x 10 ft as common sizes. Larger panels can be custom manufactured, with sizes up to 8 x 24 ft for panelized systems and similar uses.

Common OSB panel sizes (APA)
Panel sizeWidthLengthArea
4 x 8 ft4 ft8 ft32 ft²
4 x 9 ft4 ft9 ft36 ft²
4 x 10 ft4 ft10 ft40 ft²

Area A = W x L. This is nominal face coverage before waste, cuts, openings and layout losses. Some panels are made slightly under 48 x 96 in. (“sized for spacing”) to allow gaps.

For panel weight see the Plywood Weight Chart, which also helps compare similar panels.

OSB Sheet Coverage and Quantity

Panel area, sheet count and waste.

Panel area and sheet count

A = W × L    N = ⌈ Aproject / Apanel ⌉
2

960 ft² With 4 x 8 Panels

Given: Aproject = 960 ft², Apanel = 4 x 8 = 32 ft².
1
N = ⌈ 960 / 32 ⌉ = 30
2
With an illustrative 10% waste allowance: 30 x 1.10 = 33.
Result: 30 sheets minimum; 33 with 10% waste

What it means: The 10% is an illustrative estimating assumption, not a code or APA requirement. 4 x 9 panels give 27 sheets and 4 x 10 panels give 24 sheets for the same area before waste.

For project area use the Square Footage Calculator, and for roofs the Roofing Calculator and Roof Pitch Calculator.

OSB vs. Plywood Thickness

A short comparison.

Both OSB and plywood are wood structural panels and both can carry APA ratings. Equal fractional thickness does not mean identical construction, and Span Rating and grade control the intended structural use.

APA lists different Performance Category sets for the two products. See the Plywood Thickness Chart for plywood sizes. This page does not compare the two in full.

OSB Thickness and Moisture Exposure

Bond classification is not decay resistance.

Bond classification describes adhesive moisture resistance, not decay resistance.

  • Exposure 1: handles moisture during construction and similar conditions; not for permanent outdoor exposure.
  • Exterior: withstands repeated wetting and drying or long-term weather exposure.

Bond classification does not affect strength or Span Rating and does not provide fungal-decay resistance. APA recommends pressure-treated panels for ground contact or very wet conditions.

OSB edges swell when wet, so APA recommends a minimum 1/8 in. gap at panel edges. Standard OSB is not “waterproof.”

How to Choose the Right OSB Thickness

A sequence, not a single number.

  1. Identify the application: wall, roof, subfloor or single-layer floor.
  2. Determine support spacing: studs, rafters, trusses or joists.
  3. Determine the required Span Rating.
  4. Check the Performance Category for that rating.
  5. Check the strength axis.
  6. Check edge-support requirements.
  7. Check loads and local code.
  8. Check flooring, roofing and cladding requirements.
  9. Verify the APA or agency stamp.

For framing lumber sizes see the Lumber Size Chart.

Common OSB Thickness Mistakes

Errors that fail inspection.

Selecting by thickness alone

Check the Span Rating.

Ignoring Span Rating

It sets the allowed support spacing.

Reading 24/16 as panel size

It is not 24 x 16 in.

Treating 23/32 as exactly 3/4

They are different designations.

Assuming caliper equals the fraction

PS 2 allows a tolerance.

Subtracting 1/32 from every panel

It is a tolerance, not a deduction.

Ignoring the strength axis

Orientation matters for roofs and floors.

Wrong orientation on roofs or floors

Strength axis across supports.

Ignoring edge support

Roof spans change without it.

Confusing Rated Sheathing with Sturd-I-Floor

Different rating systems.

Using a roof rating as a floor rating

Read the correct component.

Treating code minimum as best floor stiffness

APA guidance is higher.

Ignoring finish-floor requirements

Follow the flooring maker.

Assuming ratings match across products

Check each stamp.

Assuming OSB is waterproof

It is not.

Ignoring wind and snow loads

Local loads govern.

Ignoring the grade stamp

It identifies the panel.

Using an unstamped panel

Do not rely on thickness.

More references are in the Construction Charts hub.

OSB Thickness FAQs

Short answers to common OSB thickness questions.

Print This OSB Thickness Chart

Use your browser to save this page as a PDF for a job-site binder or estimating folder. Interactive sections are hidden when printing.

Performance Category chartSpan Rating tablesTolerance windowSheet size and quantity formulas

Cite or Embed This Chart

Reference this OSB thickness chart on your own site. Copy the code below and keep the link to this page.

<p>OSB Thickness Chart via <a href=”https://concretecalculate.com/osb-thickness-chart/”>ConcreteCalculate.com</a></p>